VC121 / BAIRD [Video recorder]

The EURAS repair tip database for professional technicians and service engineers supplies the following faults for VC121 / BAIRD.

List of fault symptoms:
  • From switch on the drum turns.
  • When timer information is sent from RCU display shows ERR.
  • Servo hunting (capstan). Sound warble. (VC121 tip from BAIRD)
  • Appliance constantly changes between LP and SP modes.
  • No breaks, tape loop.
  • Will not accept a cassette. Display indicates power up.
  • Sound is distorted on LP with E180 cassette.
  • Intermittently no FF or REW.
  • Tuning drifts when any function selected.
  • No tuning.
  • Tuning memory does not function.
  • Dead.
  • Occasionally loss of colour in playback of own and prerecorded tapes.
  • Cassette does not load or unload.
  • FF and REW do not function. (BAIRD - VC121 information)
  • Functions do not operate and clock display is missing. (VC121 tips)
  • When tape is loaded or recording the tuning drifts.
  • Tape not being accepted, appliance switches off with cassette symbol flashing.
  • Functions do not operate and clock display is missing.
  • No functions, no display. (VC121 tip from BAIRD)
  • Recorded sound is poor.
  • Recorded sound is poor.
  • Brakes do not function, belt off and loop in tape.
  • Timer information errors from RCU when more than 9 feet away. (VC121 BAIRD repair tip)
  • After approximately 5 seconds after the tape has been loaded the appliance switches off.
  • Horizontal distortion on verticals of PB picture. Also drum servo very sensitive and anomalies when touched. All other functions ok.
  • Intermittent display and/or functions.
  • Wowing in LP mode.
  • Intermittent display and/or functions.
  • Would only power up for about 4 seconds then shut down. Would not accept a cassette, display ok.

Tips are coming from EURAS customers, workshops and payed technicians from all over the world. BAIRD VC121 fails can be better solved.

If BAIRD VC121 fails, this information will help you. Here you can only see the symptom list, to access remedies, you must register.

With help of this list a solution is found often when BAIRD VC121 fails.

For VC121 there are 3 compatible appliances known and can be listed.


Do you want to see this remedies/cures for repairtips?   Register here for the EURAS System
Please note: access to the EURAS System can be granted only to professional technicians/household electronics repair shops/Video/TV which are authorized for service by a manufacturer, or can prove to be professionally certified to do repairs on electronic appliances. You will be asked for a statement and information accordingly during registration.

If you do not qualify as stated above and you have an appliance that needs technical service, we do recommend you to contact the manufacturer (for example through his website) or go to a professional Video/TV/household electronics repair shop close to you.

Already registered? open VC121 BAIRD in EURAS

All details on the EURAS System: English | Deutsch | Français | Italiano | Español | Magyarul | Português | Polski | Română | Greek |


Back to EURAS Homepage >> All manufacturers >> BAIRD tech tips  












Last updated: 14. Oct 2008 01:52:12 MET, doccode ISO9002AS168EKA200805C EURASMOP

Responsible for the content: EURAS International GmbH, Eime, Germany.
All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.