List of fault symptoms:
  • No synchronization in picture centre on PB of own recordings.
  • Low or dull sound in EE and in REC.
  • No sound on EE operation.
  • Autofocus does not function.
  • No function with battery.
  • During camera operation the sound crackles (intermittent fault).
  • The appliance shuts down after approximately 10 seconds.
  • With the battery the camera only operates for a short time.
  • The diaphragm cannot be adjusted. The screen is still light.
  • No camera picture, during recorder operation the appliance switches off immediately.
  • Displays "BATT" at power supply function then switches off. (VCC836 tip from BAUER)
  • Cylinder motor runs out of control and appliance switches off.
  • Poor PB and EE picture. No PB in RF.
  • Recordings on 90 mins cassettes show wow and flutter. The tape will not rewind.
  • The appliance cannot rewind the cassette to the start. The capstan barely turns.
  • Recorder picture on TV is OK, picture rolling in viewer.
  • When inserting the cassette the appliance switches off.
  • Laces in, unlaces and switches off.
  • When operated through the power supply unit the appliance shows "BATT" and then switches off.
  • No colour recording possible.
  • Camera picture flashes.
  • No playback picture, but the recording is ok.
  • No functions.
  • Sync. interference in centre of picture in PB. Interference recorded but cannot be detected in viewer. Only occurs when battery is half full and outside temperatures are high.
  • During camera operation the colour flickers.
  • The viewfinder record LED lights up intermittently.
  • Motor zoom only works in one direction or not at all. (VCC836 tip from BAUER)
  • The viewfinder picture is missing.
  • Laces up, immediately unlaces and switches off. (VCC836 tip from BAUER)
  • No start-up.
  • No characters in the control unit display, control functions are otherwise ok.
  • No sound on the earphone socket.
  • Sound fails frequently. Sometimes it is also too muffled or too soft.
  • Dark picture on camera function.
  • On PB only one half of the picture can be seen. The videohead is ok.
  • During record running noises are recorded when zooming.

If BAUER VCC836 fails, this information will help you. Here you can only see the symptom list, to access remedies, you must register.

With help of this list a solution is found often when BAUER VCC836 fails.


Additionally to repairtips or service information VCC836 is linked to 5 components (IC's and/or transformers) in the Tectra database, through which you can identify electrical compatibilities (crossreferences) in appliances.


For VCC836 there are 11 compatible appliances known and can be listed.


Do you want to see this remedies/cures for repairtips?   Register here for the EURAS System
Please note: access to the EURAS System can be granted only to professional Video/TV/household electronics repair shops/technicians which are authorized for service by a manufacturer, or can prove to be professionally certified to do repairs on electronic appliances. You will be asked for a statement and information accordingly during registration.

If you do not qualify as stated above and you have an appliance that needs technical service, we do recommend you to contact the manufacturer (for example through his website) or go to a professional household/TV/Video electronics repair shop close to you.

Already registered? open VCC836 BAUER in EURAS

All details on the EURAS System: English | Deutsch | Français | Italiano | Español | Magyarul | Português | Polski | Română | Greek |


Back to EURAS Homepage >> All manufacturers >> BAUER tech tips  












Last updated: 16. Oct 2008 05:08:18 MET, doccode ISO9002AS168EKA200805C EURASMOP

Responsible for the content: EURAS International GmbH, Eime, Germany.
All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.