2000 / DEMOLUX [Projectors]
The EURAS repair tip database for professional technicians and service engineers
supplies the following faults for 2000 / DEMOLUX.
List of fault symptoms:
- Top part of the picture is too wide, the bottom part is too narrow
- Distorted low with buzz similar to quad coil off.
- RL24 (2K2) in line scan circuit burnt.
- Three coloured lines at top of picture when channel change selected.
- Does not work on a 12V supply, only on mains supply. (2000 tip from DEMOLUX)
- No or poor picture. (service info for DEMOLUX -2000)
- Unstable program lock. (DEMOLUX - 2000 information)
- Hum in audio. in standby. (extract of circuit diagram attached)
- Oversized picture on top and narrow picture at the bottom.
- Black and white flash on Canal Plus intermittently.
- Channel sequencing.
- Rippling effect on picture. Sound squealing.
- Line jitter at low signal levels (20"Models).
- Blank raster. (+ extract of circuit diagram)
- Only top two thirds of picture are scanned. Picture folds over.
- Rolls and flips over 1 or 2 times a min intermittently.
- Flyback lines present regardless of height.
- No channel search.
- Unstable picture. Patterns in picture.
- Very bright screen with low height and top foldover. Screen control seems to act as a height control.
- No signal. via SCART. OK via SCART .
- Crackling audio. at low volume. (2000 tip from DEMOLUX)
- Frame cramped and rolling at switch ON.
- TR112 and T102 line output transformer both S/C. (20").
- No vertical synchronisation. Excessive vertical size. (with circuit diagram extract) (DEMOLUX - 2000 information)
- No 10V power supply on pin 15 and 16 of IP01. No signal on pin 14 of IP01. (part of circuit diagram displayed)
- No reception. No picture, no sound. Intermittently, carrier or picture appear then disappear straight away. Channel display ok. (picture attached)
- High contrast. (+ extract of circuit diagram)
- No vertical stability (sync). If left horizontal line appears after a few mins. (part of circuit diagram displayed) (2000 tips)
- 4" of distorted field scan.
- Standby LED flickers on a regular basis.
- No video with CPC464 computer.
- Vertical deflection is defective.
- Line collapse and burn damage.
- No reception.
- Tuning fault, skips channel numbers when operating the selection button.
- Intermittent breaks.
- No OSD. Tuning OK .
- Sound barely increases and programming menu does not appear.
- Ragged verticals at high brightness.
- Lacks 2cm in width. Flyback at top of picture. Chroma flashing. (+ extract of circuit diagram)
- No start-up. Standby LED lit . (part of circuit diagram displayed)
- Cramped field with low height.
- Impossible to change channels by RC. (extract of circuit diagram attached)
- Set intermittently displays a narrow, rippling picture.
- 1.6A fuse blows at switch on.
- Low HV.
- Poor synchronisation.
- No picture and sound is ok. Whistling of the power supply transformer. Dark screen becoming blue then pink. No OSD. (+ extract of circuit diagram)
- Dark picture. Audio OK . (extract of circuit diagram attached)
- Line foldover in centre; ringing and goes off tune. (service info for DEMOLUX -2000)
- Enter service mode.
- No start up. HT increases for 1 sec then stops, even standby. (extract of circuit diagram attached)
- Shuts down.
- Picture flashes on and off when first turned on.
- Loss of channel memory.
- No image content, HF noise only. (part of circuit diagram displayed)
- Mains fuse blows at switch on. No S/C. (with circuit diagram extract) (2000 tips)
- Cuts out when cold. Standby LED on front panel is lit. Occasionally picture returns by tapping towards HT mains, in black and white or in colour.
- Erratic functions.
- Height varies or intermittent field collapse.
- Replacement of integrated circuits by ST6392B1/TT.
- After a few mins starts to whine loudly and ragged picture. No adjustment of sound.
- Very slight hum in the speaker in standby.
- Transistor TP10 (S2000AB) fails after a few days.
- Picture covered in light, thin bands.
- Non-linear scan. Cramped in middle and stretched at top and bottom.
- Flyback lines with horizontally centered TXT underneath.
- Interference on channel 3 and channel 4.
- Line foldover in the middle of screen. Chrominance fault in B/W intermittently.
- No signal.
- Enable Hotel mode.
- No audio. after a few hours.
- Line transistor is defective. After replacement defective again after 5 min.
- Modification to prevent hum in standby mode.
- Line BU (BU508) becomes warm and blows. At base of BU there are double pulses.
- Excessive horizontal size. No horizontal synchronisation.
- Blue picture. Retrace lines.
- TXT lines through centre of picture.
- Cannot switch channels using keyboard and RC.
- Child lock key is indicated on screen.
- No +13V or +25V. Appliance starts up. (extract of circuit diagram attached)
- Picture is blue or red with flickering colours causing picture to flash. Picture OK when warm.
- Intermittent severe hum bars when warm.
- Bands moving upward. Line tearing.
- Ringing verticals. (2000 tip from DEMOLUX)
- PSU transistor blown.
- Vertical foldover. (service info for DEMOLUX -2000)
- White, bright image, image barely recognizable. (picture attached)
- No field sync when brightness increased.
- Bright line across screen. i.e frame cross point. (2000 DEMOLUX repair tip)
- Three inches in from left - "ghosts" (white lines).
- Intermittently whistle from the horizontal output stage.
- Reduced vertical size.
- Comes on for a short time.
- Channel selector switches are pushed in. (2000 DEMOLUX repair tip)
- Partial collapse of picture. Flashing lines at bottom of picture.
- A faint patch develops on the left hand side about half way down on a blue raster. This shows up as a slightly darker shade of blue, vertical lines on the left side bend around this patch.
- Unstable picture.
- Intermittent tuning drift, humbar or field roll.
- Down the centre of the screen are flyback lines with teletext lines below.
- Line tearing.
- Pink screen at start up then picture comes in black and white for 1 min.
- Intermittent signal. Weak signal.
- Noise bars.
- Apparent cut off lines and blue flashes.
- When teletext subtitles are present the brightness level falls. (+ extract of circuit diagram)
- Burning/fuse not blown.
- No image content, rainbow colour at upper edge. (with circuit diagram extract)
- Boundary lines on the top. (2000 tips)
- Three or more flyback lines at the top or bottom of the scan. (+ extract of circuit diagram)
- LED is red. No function from board or RCU.
- Vertical deflection defective. Dark picture.
- Vertical bar.
- No picture, just patterning.
- Black patch at the top of the picture.
- Whistling chopper transformer.
- 3 coloured lines on upper picture edge, if appliance is cold. (2000 tip from DEMOLUX)
- Slow start-up. when cold.
- Horizontal collapse.
- Red picture then blue or green on a black and white TV. No PB, sandcastle ok. Power supply correct. (part of circuit diagram displayed)
- Black screen. No audio. after warm-up.
- White raster with visible retrace lines. Pink raster when hot. OSD OK.
- Intense vertical white line in middle of the screen (N/S). (+ extract of circuit diagram)
- Four inches of distorted field scan.
- No picture. Blank raster (intermittently).
- Horizontal collapse. intermittently.
- Coloured horizontal lines over the screen. Black and white picture.
- No remote volume/colour.
- Partial frame collapse. Flickering lines at bottom of screen.
- TP01 (BUT12A) fails after longer operation while.
- Blank raster. No audio. (with circuit diagram extract)
- Teletext is missing and picture switches off and on.
- The channels have shifted 9 channels.
- No picture. in PB.
- 95V rail low and set-up potentiometer inoperative.
- Searches for channels continuously.
- Switches off by itself (at start-up).
- No channels.
- Intermittently trips when starting up. After starting up, frame frequency oscillates for a short while.
- Low sound centre of v/c. Sound falls off as v/ c increases.
- No tuning. Skips channel numbers when selector button is pressed.
- TP32 fails at switch on. (+ extract of circuit diagram)
- Band on picture
- Vertical foldover at top and bottom. (service info for DEMOLUX -2000)
- Vertical collapse (after warm-up).
- Vertical strips of shading that vary with brightness.
- Blown fuse FD702 (8A) on DC-DC converter board.
- Always comes on in standby. Could remove standby by remote or channel step. When on sound and picture ok.
- Vertical white line on the right side of the screen. (with circuit diagram extract)
- No OSD.
- S/C in line output transformer and transistor.
- Horizontal bar in middle of screen. (extract of circuit diagram attached)
- Top part of the picture is too wide and bottom part is too narrow.
- Bright line and slight line foldover on bright scenes only.
- Switches to standby. intermittently. (+ extract of circuit diagram)
- CTV does not start up. Standby LED on.
- Vertical lines at edge during EE operation and via AV. (with circuit diagram extract)
- Intermittently show at start up. In the channel adjustment menu, no access to the SECAM-PAL standard. Poor reception in TXT mode.
- White screen then flyback line and goes into safety mode. (part of circuit diagram displayed)
- Vertical size varies. Vertical bounce. Fault occurs intermittently. .
- Partial frame collapse. Top two thirds only and foldover.
- Distorted picture, buzzing from left hand side and intermittent colour.
- No functions.
- Intermittently dead.
- Picture has hum bars which also affect the colour.
- Tuning does not function, beat patterning from raster and simulated noises on audio. (DEMOLUX - 2000 information)
- When volume level is increased the sound crackles and the colour drops out.
- Field collapse or scan is reduced, severe non linearity.
- Picture size slightly diminished. (DEMOLUX - 2000 information)
- Field scan reduces to few ins then collapses after short time.
- "Lock" on the screen.
- Attempts to start up, then dead. LED lights up brightly for a moment, then dims slowly.
- Snow in picture. intermittently.
- No picture or faint picture if A1 advanced.
- S2000 fails after short while. (2000 tips)
- Picture is pulled at the top. Poor line sync. (with circuit diagram extract)
- Does not start up unless switch held in. Goes into standby when released. (service info for DEMOLUX -2000)
- Vertical collapse.
- Flyback lines. at top. (with circuit diagram extract)
- No start-up. Clicking noise. (with circuit diagram extract)
- No or poor audio.
- Trips. after a while. (service info for DEMOLUX -2000)
- Text on picture when warmed up. Only noticeable in top corner of screen (left).
- White screen. Blank screen. (+ extract of circuit diagram) (service info for DEMOLUX -2000)
- Vertical ripple.
- Vertical foldover. in the centre.
- Line foldover blowing line O/P transistor.
- Low brilliance (no b 1 clamp).
- Frame over scan.
- Line output transformer TX and TR S/C.
- No start-up (when cold).
- Crackling in the sound via the aerial and via scart. Speakers ok. (with circuit diagram extract)
- Patch missing from top of frame.
- Set won't power up unless the on/off switch is held on (PC1139) remote panel. (DEMOLUX - 2000 information)
- Slow start-up.
- Field collapse or partial collapse with no video information.
- Every 2 days S2000 fails without an obvious reason.
- Faint picture. Contrast and brightness controls inoperative.
- Production changes: tuner types.
- Line output transistor fails repeatedly.
- Only faint watery image when first anode increased.
- Frequency does not agree with the channel.
- Dead (intermittently).
- Hum bar present on picture going upwards.
- Foldover or frame cramp.
- Reduced vertical deflection. intermittently.
- Sound and picture are missing, slight line whistle.
- Tuning fault (channels jump continually, if the battery converter TA127 has a high ambient temperature).
- Screen goes red then intermittently becomes black. Fault occurs at switch on or after a few hours.
- No sound or picture (faint line whistle).
- At start up does not hold vertical stability. Everything returns to normal after a few moments. (+ extract of circuit diagram) (service info for DEMOLUX -2000)
- Vertical collapse (intermittently). (with circuit diagram extract)
- Occasionally picture is present by "flashes" and jumps but in black and white. No sound. When increasing volume, noise is present which varies with power. (with circuit diagram extract)
- Excessive horizontal size. at top. Reduced horizontal size. at bottom.
- No functions. Standby LED lit .
- Picture rolls.
- Switches to standby (at start-up).
- No VOL via RC.
- Snow in picture. Weak signal.
- Bright raster. Flyback lines. (+ extract of circuit diagram)
- After 10 mins picture disappears. (2000 tips)
- Picture is oversized on top and narrow at the bottom.
- Blanking.
- Low contrast.
- Green and red lines in upper part of screen.
- Slow line speed and appliance trips. (service info for DEMOLUX -2000)
- No HF, only appears intermittently like motor boating. OK in scart.
- Colourful stripes on upper picture edge.
- Weak signal. intermittently.
- Intermittently appliance remains in standby and brightness exaggerated.
- Signals are missing or gain low.
- Ripple effect on all vertical contents of picture; can be reduced by lowering the brightness or contrast level.
- No start-up from standby with RC.
- Poor horizontal synchronisation. Distorted picture. at top. (extract of circuit diagram attached)
- Flashover in picture on band I. (with circuit diagram extract)
- Dead. LED lit. . (DEMOLUX - 2000 information)
- No picture. Black screen. No RC functions. No front panel function. (picture attached)
- No video, not even in auxiliary. Appliance switches on like in video mode. Sound ok.
- TV switch on in standby with a slight hum in the sound but does not start up. DP21=123V but DP23=5V. (with circuit diagram extract)
- Chassis identification (2000 DEMOLUX repair tip)
- No picture. Dark screen, even when going via scart. Sound and display ok. (with circuit diagram extract) (service info for DEMOLUX -2000)
- Intermittent picture or snow. (with circuit diagram extract)
- No image on channel 99. (extract of circuit diagram attached)
- No start-up (intermittently). (picture attached)
- 12V rail is missing.
- No power supply. Mains, primary ok, line transformer seems ok. BU on the chassis seems poor but ok once removed. (with circuit diagram extract)
- Picture pumping slightly after the 33V are restored. (picture attached)
- Ripple on picture (more at top half.
- Unlocked colour.
- Line output transistor S/C, blows again on replacement.
- Cannot increase HT beyond 93V, cogging and bent verticals.
- Volume increases without a reason.
- Poor sync in computer mode.
- Low humm in vertical lines. (part of circuit diagram displayed)
- Only white vertical lines in centre of picture.
- Picture is poor and pale, contrast and brightness controls do not function.
- Intermittently picture rolls, once or twice per minute.
- Line wobbling.
- Mains hum, distorted scan, and gross purity errors.
- Vertical black line in centre when contrast is high.
- Random dot pattern (model MC01 when used with battery converter TA127A).
- Vertical line. in the centre.
- Cogging when warm.
- Text lines on ITV and CH4 only.
- Noise in picture.
- Drifting field hold.
- Tuning fault (No scan tuning forwards, backwards and memory ok). (2000 tips)
- Removing the case.
- Switches off by itself. Clicking noise.
- Whistling on line.
- Low HT, won't adjust with preset, verticals cog and bow, dependent on beam current.
- Blank raster (intermittently). Audio OK .
- Horizontal deflection is missing. Protective circuit disconnects. Standby-point blinks.
- Picture flickers slightly from bottom to top. (part of circuit diagram displayed)
- Power supply fault. (+ extract of circuit diagram)
- No horizontal deflection. Standby LED flashes .
- Memory is lost on channel 1.
- As sets warms up teletext lines start to show in top left hand side only.
- Very bright flyback lines. (service info for DEMOLUX -2000)
- Trips when brightness set low.
- Tuning lock.
- No 150V. Channel LED OK.
- Ripple on picture.
- No picture, no sound just fizzing noise and smell like a childs cap gun.
- Ripple on verticals.
- When first switched on sound produces a loud buzz, operation of volume control makes no difference and although the EHT present no raster.
- TXT lines visible.
- Reduced vertical and horizontal size. (2000 tip from DEMOLUX)
- Hiss in audio. at low volume.
- Reduced height. No sound, no picure and flyback lines.
- Only high channels. Normal channels don't synchronize.
- Does not switch to standby.
- Stripes in picture. Sound crackles. Intermittently no videotext.
- Pink screen at start up, then B/W picture. Picture OK after one minute.
- Dark picture. (extract of circuit diagram attached)
- No picture. Audio OK .
- Circuit IL01 (TDA8218). Loss of colour on some VHF or UHF channels. (with circuit diagram extract) (service info for DEMOLUX -2000)
- Vertical foldover. Vertical collapse. after a few minutes.
- Tripping. (picture attached)
- Low brightness. No colour. (+ extract of circuit diagram)
- Black area in top right hand corner of screen.
- Flyback blanking is defective. Flyback stripes. (2000 tip from DEMOLUX)
- Horizontal line.
- Dead. Slight noise coming from loudspeaker at start-up.
- No picture or sound. White screen (no snow) with flyback lines.
- When channels are changed the appliance trips.
- Flickering picture.
- Vertical roll. Poor synchronisation.
- Empty raster, slight pattern, no sound.
- Bright blue raster and flyback lines.
- 50Hz hums in the speaker in standby.
- Green picture.
- Picture starts 2 columns to left with Sinclair "QL".
- Trips with low brightness setting. (Only 20" appliances)
- No picture in scart input, sound is normal. Picture normal in scart output.
- Mains hum: distorted scan gross purity errors.
- On certain channels the text is distorted.
- No standby, no start up. 12V pulsates on pin 16 of power supply IC. 12V if point 16 lifted. (extract of circuit diagram attached)
- Cannot be switched on or switched to standby. Standby indicator does not light up. (2000 tip from DEMOLUX)
- Vertical deflection has collapsed to a bright line in the middle of the screen. (picture attached)
- Cannot store channels 1-8.
- Switches to protection mode. (picture attached)
- Fuse on the secondary side of the mains transformer blown.
- Channel 1 lights but set is dead and no sound/picture.
- Horizontal white line. Vertical fault.
- Random fuse blowing.
- Line down centre of screen only (line collapse)
- Horizontal foldover. at bottom.
- Switches off by itself. after a while.
- Picture stretched and cramped in centre.
- The appliance is dead (FS2 blown), reduced in height and has no sound.
- Poor audio.
- No colour; just faint blue cast.
- No field sync while line scanning suffers from jitter at the top of the picture only. (2000 tips)
- Vertical collapse following field drift.
- Clicking noise.
- Picture turns green or blue when changing channels. If you change channel again, picture is ok. (extract of circuit diagram attached)
- No audio (intermittently).
- Black screen. Audio OK .
- 95V rail is high and cannot be set up.
- Noisy power supply at switch on from cold. Appliance switches to standby. All is normal after 1 minute approx. (part of circuit diagram displayed)
- No TXT and picture going OFF/ON.
- Stuck in AV as if slow switching via scart. (+ extract of circuit diagram)
- No blue. (part of circuit diagram displayed)
- Field hold drifts then jittering/vertical collapse.
- Parts fitted (unknown) set still won't tune.
- Dead, at switch on standby LED on for a few secs. (picture attached)
- Ragged/tearing picture. Worse at high brightness.
- Intermittent colour. (part of circuit diagram displayed)
- High HT, HT control inoperative.
- Noise on channel 09 (Band I) - colour picture. (2000 tips)
- When selector button is used, programmes are skipped.
- No synchronisation. (with circuit diagram extract)
- Disable hotel mode. (DEMOLUX - 2000 information)
- Distorted field scan with excessive height.
- White screen. No image. No image content. No noise. (extract of circuit diagram attached)
- Horizontal jitter.
- At switch on LED comes on for a short time then everything goe off. (picture attached)
- Lines in picture. at top. (with circuit diagram extract)
- Poor vertical linearity.
- Blows main fuse on transformer. Line output transistor does not go s/circuit
- When volume is turned up the sound is lost.
- No picture. (extract of circuit diagram attached)
- Intermittently starts up or shuts down. (2000 tips)
- Dim picture. No brightness control. No contrast control.
- Vertical foldover at top.
- Low audio. (DEMOLUX - 2000 information)
- No picture, no sound and faint line whistle.
- 4 dotted lines on top half of picture from left to centre and right to centre.
- Feed resistor O/C.
- Cannot be switched on or switched to standby. Standby indicator does not light up. (DEMOLUX - 2000 information)
- Poor display.
- Smearing in picture. Ringing in picture.
- Dead. Clicking noise. (part of circuit diagram displayed) (2000 tip from DEMOLUX)
- No reception on band I, or image flickering only. (part of circuit diagram displayed)
- No 33V on point 4 of tuner. Ok in scart. (picture attached) (service info for DEMOLUX -2000)
- Ragged verticals more evident when picture bright.
- Small horizontal coloured lines over the whole screen and flickering. OK in black and white. (picture attached)
- Tuning drifts.
- TP01 (BUT12A) fails after operation while.
- Horizontal lines.
- Grainy picture on all channels.
- Starts up for a short time, then switches off. Standby LED lights for a short time. (service info for DEMOLUX -2000)
- Blocks in all functions after fitting the TXT board VT8004. Screen remains dark.
- Reduced height raster (no picture or sound).
- Snowy picture, channels 1 to 8 cannot be stored in memory, but 9 to 16 can.
- Several red, green and blue lines in upper picture part. Intermittently vertical stripe. After short switch off, picture is OK again.
- No signal (intermittently).
- Vertical collapse or linearity faults.
- Occasional collapse.
- No reception. in TXT.
- Scan is non linear, cramped at centre, top and bottom are stretched.
- Image poorly blue, no image content, flyback lines.. (extract of circuit diagram attached)
- Intermittent field roll (flips over 1-2 times a minute).
- Horizontal foldover (intermittently). (service info for DEMOLUX -2000)
- Loss of picture or loss of brightness and contrast (very faint colour). (+ extract of circuit diagram)
- Excessive vertical size.
- Occasionally field bounce and height varies.
- After approx 1 week IC902 loses its memory.
- No 95V on line output transistor.
- Incorrect line frequency.
- Poor picture. Negative picture.
- Poor synchronisation (after warm-up).
- Picture blanks out, parts of the screen go black or thick lines over picture (may take days for the fault to show).
- After turning up brightness and contrast, sound and synchronisation is lost.
- Line whistle.
- No raster.
- BUT12 S/C and TEA2261 blows, after replacing them, TV does not start up and sawtooth on TEA2261 pin 10, functions in pulses. (extract of circuit diagram attached)
- No RC functions.
- Rhythmic interruption of the picture, sound is correct. With the oscilloscope identical interruption of the video is noted on pin 6 of the IF module.
- On a very dark picture, very dark red vertical bar at the far right of the screen. (picture attached)
- TP01 (BUT12A) fails after longer operating time
- Low 95V rail and set-up potentiometer does not function.
- Snowy picture which does not vary even when changing channel.
- Partial vetical collapse and flickering lines at the bottom.
- Hum bar.
- U1 is instead of 84-90V only approx. 60V. Current uptake higher than 100W. (extract of circuit diagram attached)
- Picture is bright and white with flyback lines. (part of circuit diagram displayed) (2000 tips)
- No tuning. OSD OK . (extract of circuit diagram attached) (DEMOLUX - 2000 information)
- No horizontal deflection. (extract of circuit diagram attached)
- Flyback lines in the top part of the picture and IL01 (TDA8218) blows when warm. (+ extract of circuit diagram)
- Vertical foldover at bottom.
- Frame cramp after 5mins. TIP29 & TIP112 replaced.
- Missing video with CPC464 computer.
- Top of picture distorted. Incorrect linearity, 5cm horizontal line from top. Flickering colour.
- Dark picture and white bars with TDA8214B. (picture attached)
- No B drive. (extract of circuit diagram attached) (2000 tip from DEMOLUX)
- TP32 (BU508) and TL37 (BU508) fail immediately after switch on. (with circuit diagram extract)
- Severe line cogging.
- Severe cogging.
- HT rail is high, voltage cannot be reduced by the set HT potentiometer.
- No sweep tuning upward. Downward tuning and store function are OK.
- No picture, maybe no sound. Channel indicator OK.
- Distorted picture. (service info for DEMOLUX -2000)
- No picture sync when adjusting brightness and contrast.
- Picture fades.
- No synchronisation (after warm-up).
- TXT is muddled or missing.
- Coloured flyback lines and poor picture.
- Non linear and field cramp.
- No start function with RC. With mains switch appliance is set to standby. (with circuit diagram extract)
- No picture and no sound. CRT filaments lit.
- No sound. Bright horizontal line. (part of circuit diagram displayed)
- Loss of colour in Secam. (picture attached)
- Bright picture. Flyback lines. (2000 tip from DEMOLUX)
- No function possible, for the most part display is present on the screen.
- Standby LED is dark.
- The T9062V line driver transistor TR67 is short-circuit and the safety resistor R222 damages its collector circuit.
- No picture. No sound Channel indicator and channel change OK.
- No picture (after a few minutes).
- Failure of IC293. Loss of tuning memory.
- Picture pulsates between or snowy picture in tuner reception. Ok in scart. (2000 tips)
- Intense, vertical white line in middle of screen (N/S). Sound OK. (DEMOLUX - 2000 information)
- Corrugated ripple on vertical content.
- Loud hum, sounds like mains transformer being overloaded when first switched on. Picture present , no sound, only hum. After 1 minute set shuts down.
- No 12V rail. (DEMOLUX - 2000 information)
- Snow in picture. when cold.
- Set dead. 20".
- Drifting field hold, followed by jittering and field collapse.
- Lines at approx top 2 inches of picture.
- Text interference on ITV and CH4. (2000 tips)
- No function (preceded by bang).
- BUT12 S/C, fuse and TEA2261 defective. (picture attached)
- Vertical herringbone patterning which is most noticeable at very low contrast settings on 14" sets.
- Crackle on sound with volume at min. Ripple on picture.
- Picture flashes. Line amplitude reduced, flyback raster at the top. Weak EHT. Goes into safety mode when power supply voltage increased.
- Picture rolls. No picture. after a while.
- Verticals cog and bow with beam current variations.
- Cycles on/off. intermittently.
- No front panel function. RC OK.
- Top 1" of picture missing.
- No picture (intermittently). Audio OK .
- Colour fades after approx 30 mins.
- No channel display or tuning.
- No start-up from standby. (picture attached)
- Excessive HV.
- Reduced vertical deflection.
- Switches to protection mode (intermittently). (2000 tip from DEMOLUX)
- PSU attempts to start once. LED flashes briefly.
- Black and white TV with predominant red in the tuner and in scart. If you cut the colour, black and white is ok. (with circuit diagram extract)
- No picture, only snow (intermittently).
- TDA1170S frame chip keeps destroying itself.
- Jumpy, fuzzy picture.
- Picture has band, with tearing, that moves up the screen.
- Loss of sync and sound when brightness or contrast adjusted.
- No display. Poor sound adjustment and channel reception. (extract of circuit diagram attached)
- Cut-off adjustment.
- Reduced horizontal size. No colour. (picture attached)
- Enable child lock.
- Colours are displaced. Colour bleeding. (part of circuit diagram displayed)
- Power supply BUT12 S/C after replacement. No FBT, secondary power supply collapses. (+ extract of circuit diagram)
- Drop out in the sound muting and channel search during up and down program switching.
- Only partial picture with bottom foldover. (service info for DEMOLUX -2000)
- 3" white lines from left.
- Picture loss in horizontal strokes.
- Colour is ok at switch on then colours are unlocked then finally colour is lost.
- Raster is bright blue with flyback lines. (extract of circuit diagram attached)
- Stuck in standby. (with circuit diagram extract)
- Shuts down. after start-up.
- No field output.
- Hums when standby selected.
- Rolling picture with horizontal ripples.
- Intermittent white raster with flyback lines visible.
- No or jumbled TXT.
- No colour. (extract of circuit diagram attached)
- Red streaking across the picture.
- No sync. No sound when brilliance or contrast selected. (service info for DEMOLUX -2000)
- Distorted audio.
- Intermittently line break after shocks.
- No synchronisation (intermittently). (picture attached)
- Trips.
- Corrugated verticals.
- Vertical bar moving across picture.
- Tube overfeeds with flyback lines then appliance goes into safety mode.
- Shadows near white lines on the left.
- Too low image width, poor lines visible on screen. (part of circuit diagram displayed)
- Increase in the transfer rate of the tube after several hours. (+ extract of circuit diagram)
- Excessive brightness. intermittently.
- Intermittently pulses off then on again.
- Bad picture in HF. (with circuit diagram extract)
- Picture becomes snowy after 10 mins and sound cuts out or becomes poor. (picture attached)
- Field collapse superimposed on picture that almost vanishes after 5 mins.
- Insufficient height with small amount of foldover at top. (2000 DEMOLUX repair tip)
- Poor colour.
- Switches to standby. (extract of circuit diagram attached)
- Lines in picture. (part of circuit diagram displayed)
- Dead. Standby LED lit . (2000 tip from DEMOLUX)
- Vertical roll (intermittently).
- Intermittently, no chroma and no sound. Vertical white bar in the middle.
- No frame sync, line lock also critical.
- TEA2261, BUT12, RP01 (0R27) and RP03 (1K) blow at switch on.
- Horizontal deflection missing.Protective circuit disconnects. Standby point flashes.
- Frame cramp at top for approx. four to five mins.
- Dead. Channel display on .
- Intermittent failure.
- Sound goes up then fades as volume control is turned.
- No picture. Flyback line as if G2 had been pressed.
- Dark band with ringing at low contrast.
- Brightness varies.
- Picture and CRT heaters are missing. (picture attached)
- Bad ripple on the picture and hum on the sound.
- Pulsating picture and incorrect line frequency.
- Weak contrast.
- Line output stage whistle. (with circuit diagram extract)
- Lines in picture. at bottom. (picture attached)
- Dead. Faint line whistle.
- Will not indicate certain channels.
- Grainy picture.
- Sound on vision.
- Pattern of white lines over the picture from cold (like a beat pattern).
- Trips. depending on picture content.
- No channel display. No tuning. (extract of circuit diagram attached)
- Intermittently stuck in standby, especially if switched on when warm. (picture attached)
- Uneven verticals.
- Noise in the speaker in standby position. (picture attached) (2000 DEMOLUX repair tip)
- Weak contrast, low video and no sound.
- Line ragging and whistle.
- Vertical line crossing the screen.
- Colour drop out after an extended operating time. Identification between Pal and Secam is critical.
- No start up unless switch held in, goes into standby when released.
- No frame scan. Line in centre of picture.
- No synchronisation. Audio OK . (DEMOLUX - 2000 information)
- Image noise in upper channels (e.g. channel 60, 99). (picture attached)
- Loss of line lock when warmed up plus popping from speaker.
- No picture, only snow.
- RL24 burnt up.
- Sweep tuning does not function.
- Poor colour. No brightness. No contrast.
- Regulation problems.
- Picture scrolls, shakes and collapses.
- No image in UHF, voltage for band switching and adjustment OK. On UHF lines pin 10 approx. 8V. (with circuit diagram extract)
- Vertical jitter. Vertical roll. after a while. (service info for DEMOLUX -2000)
- No or intermittent picture. after start-up.
- Power supply hums in standby.
- Picture rolls. Buzz in audio.
- Intermittent picture or snow or white bands horizontally. No sound at all or jerky sound when RC is used. (picture attached)
- Picture blanking in top left hand corner.
- Picture hum and picture is slightly brighter at the top and bottom. (picture attached)
- Coloured lines. on upper half screen.
- Shuts down (intermittently). (part of circuit diagram displayed)
- No store of low channels.
- Slightly undersized picture.
- No image, red raster and visible flyback lines. (with circuit diagram extract)
- No picture, no sound. Line on screen. (2000 tips)
- Picture pulsing on/off. Line collapsing. Pulsing sound.
- Sound mute, no channel by manual controls (intermittent).
- Heavy line striations and low contrast. (2000 tip from DEMOLUX)
- Noise with drop out.
- No audio (via SCART).
- No sound, no picture. No raster scanning. Line transformer ok. (with circuit diagram extract)
- Picture/raster distorted.
- Ragged verticals.
- Noise at power up.
- Line speed off and field roll.
- Blanking fault (top 1-inch of the picture is missing).
- Hum bar on picture when brightness reduced. Pic rolling intermittent.
- Streaks in picture.
- Most of the time the top verticals are wavy.
- After line output transformer has been replaced A1 voltage is missing.
- No switch on. Standby power supply ok. Standby indicator lights up.
- Brightness level drops when TXT subtitles are displayed.
- Reduced vertical size (after a while).
- The appliance scans the top 2/3rds only and folds up.
- No or poor synchronisation. Audio OK .
- No channel storing. (DEMOLUX - 2000 information)
- CTV switches off every 5 minutes. CTV includes an alarm clock and if this is disconnected the CTV has the same problem.
- No picture (intermittently).
- Squealing from PSU. (with circuit diagram extract)
- No picture. Other functions OK .
- Excessive height with poor linearity, minimal effect on the height control.
- Picture bounces vertically. Sound blubbers.
- No vertical deflection.
- No switching in PAL. Aerial ok in both PAL and SECAM. (with circuit diagram extract)
- No contrast control. No brightness control. (extract of circuit diagram attached)
- Trips. when changing channels.
- Modification in production.
- No picture - faint, watery image obtained when first anode voltage increased.
- PSU pulsates.
- No power. (2000 tips)
- Top 4-5 inches of picture cramped.
With this service information, you may repair DEMOLUX 2000 faster/better when it fails.
When DEMOLUX 2000 fails , these symptoms are known and EURAS knows the remedy/solution.
Tips are coming from EURAS customers, workshops and payed technicians from all over the world. DEMOLUX 2000 fails can be better solved. If DEMOLUX 2000 fails, this information will help you. Here you can only see the symptom list, to access remedies, you must register. With help of this list a solution is found often when DEMOLUX 2000 fails.
|
Additionally to repairtips or service information 2000 is linked to 62 components (IC's and/or transformers) in the Tectra
database, through which you can identify electrical compatibilities (crossreferences) in
appliances.
|
Chassis information is available (which chassis is built in into 2000 ).
EURAS system also knows 227 appliances having the same chassis as 2000 and can easily list them.
In the repair discussion pinboard for 2000 there are 53 replies to questions asked about 12 different repair problems. With access to EURAS you can all read them or enter your own questions and get help for 2000 from EURAS technicians or other users.
Do want to see this remedies/cures for repairtips? Register here for the EURAS System
Already registered? open 2000 DEMOLUX in EURAS
All details on the EURAS System: English |
Deutsch |
Français |
Italiano |
Español |
Magyarul |
Português |
Polski |
Română |
Greek |
Back to EURAS Homepage >>
All manufacturers >>
DEMOLUX
tech tips
(C) EURAS International Ltd.
Last updated: 30. Aug 2008 11:24:50 MET, doccode ISO9002AS168EKA200805C [cachelite] EURASMOP
Responsible for the content: EURAS International GmbH, Eime, Germany.
All rights reserved, EURAS database V2.0 (C) 2002-2008.
All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.
|
|