GDM2040 / ELSA [20" monitors]
The EURAS repair tip database for professional technicians and service engineers
supplies the following faults for GDM2040 / ELSA.
List of fault symptoms:
- Vertical convergence has shifted.
- EHT comes up for a second, then dies.
- Specifications.
- Blurry picture. in the centre.
- CENT lights and both right LEDs flash.
- Dead. Front panel LEDs flash.
- Trembles horizontally.
- After changing IC801, high voltage for 2 secs then the power- and saving LEDs flash. Geom LED is on.
- No functions.
- Does not switch on, power LED flashing.
- Switches off by itself. after start-up. (GDM2040 ELSA repair tip)
- Both LEDs flash.
- Keys do not function (except power).
- Picture shifted horizontally. on the right.
- Switches on and off again immediately. Error message and size LED light up.
- Builds up high voltage for a short time and then goes into error mode. Centre LED is still lit and power LED and power save LED flash.
- Slight flickering at the bottom side edges. Hardly visible.
- High voltage builds up at the moment of switch on. Error message: PowerSave Cent.
- Bright picture. Flyback lines.
- Strong line tearing on the whole screen. Vertical lines are zigzag.
- Starts up for a short time, high voltage builds up. After 5 mins appliance switches to standby. Mains voltages fall to approx 1/3 of their normal value.
- No synchronisation.
- No picture. Power and Power-Saving LED flash. CENT-LED lights up.
- Green and yellow LEDs flash. Geometry LED lights up permanently.
- Switches off and yellow LED flashes.
- In shut down mode but centering and power saving LEDs lit.
- After switch on high voltage is built up for a short time. H stage build up and mains chopper transformer hisses.
- Adjustments for the picture geometry are lost after changing the mode.
- Picture grows dim after some time then finally disappears.
- Terminals.
- Protection mode activated. after start-up.
- Switches off immediately. Power Save and Centre LED light up.
- Line output stage is defective.
- Supply voltage for the line end stage is not switched through via Q804.
- Picture shrinks, popping, dies and also smells. (ELSA - GDM2040 information)
- Picture is slightly blurred at the edge and picture position is wrong.
- Dark picture.
- No picture due to loss of CRT heater voltage. (GDM2040 tips)
- Vertical smearing in middle third of screen.
- High voltage builds up for a short time. Error message Cent LED on. Power-Save and Power-On flicker.
- Screen is dark, green power LED on, otherwise no error message.
- Goes into Geo fault.
- White screen. Flyback lines. (GDM2040 ELSA repair tip)
- Switches to protection mode.
- Line collapse, dim vertical bar (5mm wide, 1/3 of way from left). Visible on white raster at 640x480 and 1024x768.
- Horizontal shift, centering control does not function properly.
- Q511 is defective. Appliance does not yet function. High voltage builds up then goes down again. Goes into power save mode. Green LED goes out. Orange LED lights up.
- No horizontal deflection. Error mesage: Power Save Cent.
- No raster.
- Switches off. GEO LED lights up.
- Bright picture with flyback lines. No picture content.
- No horizontal deflection. No operating voltage. Error message: PowerSave Cent.
- Poor picture.
- No HV and LEDs flashing.
- Starts up for a short time then switches at once into power save mode.
- No HV, GEO-LED is constantly on. H-drive pulse from the N-board only for 0.5 sec., then it disappears.
- No HV. after a while.
- Switches off. Mains LED flashes green, Power-save LED and Cent-LED flash orange.
- Goes on for a short time then goes into power save.
- Squealing noise.
- Q512 (SC3998) and Q511 are S/C.
- Power supply voltage are too low (55V instead of 144V). Power and Saving LEDs flash and geometry LED is on. LOPT ok.
- Power Save and Centre LEDs light up.
- No vertical synchronisation. (service info for ELSA -GDM2040)
- Deflection fault, error message: Power Save Cent.
- Starts up and shutsdown. Power and power save LED's flashing.
- High voltage builds up for a short time and then switches off.
- At the moment of switch on high voltage build sup then appliance switches off.
- Switches off immediately. Power LED, power saving LED and geometry LED flashing.
- Cloud of smoke from the line output stage.
- High voltage builds shortly up, then error report. Geometry LED and Power save + on LED flash.
- Centre LED on. Powersafe LEDs flash. High voltage is built up for a short time.
- Power- and saving-LED flash. Geometry LED is on. LOPT is not defective. No voltage at line end stage.
- No picture. High voltage and power save light on.
- Q511 blown again after replacement.
- Repeatedly blows IC404.
- Gives off smoke.
- Short peeping at switch on. Finally Power and Save flash- Geo LED lights continuously.
- No dynamic focus. Fuzzy horizontal lines in centre of screen.
- High voltage builds up to 27100V auf. After 5 secs switches to power save. No LEDs light up.
- No HV.
- Vertical lines are sometimes duplicated.
- Vertical roll.
- No horizontal synchronisation after switched-on for 30 minutes.
- Shutsdown. Flashing orange light.
- Blurry picture. on the left (at bottom).
- Power-Save LED is on.
- Picture is completely blurred on the right, if focus control is turned, picture can be sharpened on the right then however the middle is blurred.
- LEDs flash.
- Shuts down.
- No start-up.
- Keine H-Ablenkung, Betriebsspannung fehlt. Fehlermeldung: PowerSave Cent.
- Error message: PowerSave Cent. At switch on high voltage builds up. (GDM2040 tips)
- No HV. Geometry light, power/saver lights flash.
- Error codes.
- Switches off by itself. after a few seconds. (GDM2040 tip from ELSA)
- Goes into Power Save. Geometry LED is on.
- Picture shifted to the left.
- No vertical deflection.
- IC801 (CMOS4049) fails when there are high voltage flashovers.
- Picture is unstable when switching from TXT to Graphics mode and when going from a low to high resolution graphics mode or in reverse.
- Error message: both LEDs flash on the right. CENT lights up permanently.
- Excessive brightness. Flyback lines.
- Shuts down (after a few seconds). (service info for ELSA -GDM2040)
- PSU whistles and does not oscillate.
- Appliance goes into power save mode.
- Picture absent, high voltage missing, geometry light on, power save and power light flash. (ELSA - GDM2040 information)
- Switches off after the slightest shake (at almost every site). Only by switching on again is the picture sporadically present again.
- Switches on, HT builds up briefly, then it switches to power-save. LED is on. No picture.
- Discharge of the tube. (GDM2040 tips)
- No adjustment of horizontal, pincushion and keystone balance. Defective horizontal, centering and dynamic focus.
- Power and power LEDs flash and geometry LED permanently on when mains cable inserted.
- Dead.
- Goes into standby, centre LED is on.
- Geometry error message.
- Power save and Standby flash. Geometry light permanently.
- Screen is dark, high voltage for a short time and finally appliance jumps into power save mode.
When ELSA GDM2040 fails , these symptoms are known and EURAS knows the remedy/solution.
Tips are coming from EURAS customers, workshops and payed technicians from all over the world. ELSA GDM2040 fails can be better solved. If ELSA GDM2040 fails, this information will help you. Here you can only see the symptom list, to access remedies, you must register. With help of this list a solution is found often when ELSA GDM2040 fails.
|
Additionally to repairtips or service information GDM2040 is linked to 113 components (IC's and/or transformers) in the Tectra
database, through which you can identify electrical compatibilities (crossreferences) in
appliances.
|
Chassis information is available (which chassis is built in into GDM2040 ).
EURAS system also knows 41 appliances having the same chassis as GDM2040 and can easily list them.
For GDM2040 there are 3 compatible appliances known and can be listed.
In the repair discussion pinboard for GDM2040 there are 6 replies to questions asked about 3 different repair problems. With access to EURAS you can all read them or enter your own questions and get help for GDM2040 from EURAS technicians or other users.
Do you want to see this remedies/cures for repairtips? Register here for the EURAS System Please note: access to the EURAS System can be granted only to professional
household electronics repair shops/TV/Video/technicians which are
authorized for service by a manufacturer, or can prove to be professionally
certified to do repairs on electronic appliances. You will be asked for a
statement and information accordingly during registration.
If you do not qualify as stated above and you have an appliance that needs
technical service, we do recommend you to contact the manufacturer (for
example through his website) or go to a professional household/Video/TV
electronics repair shop close to you.
Already registered? open GDM2040 ELSA in EURAS
All details on the EURAS System: English |
Deutsch |
Français |
Italiano |
Español |
Magyarul |
Português |
Polski |
Română |
Greek |
Back to EURAS Homepage >>
All manufacturers >>
ELSA
tech tips
Last updated: 06. Oct 2008 22:42:33 MET, doccode ISO9002AS168EKA200805C EURASMOP
Responsible for the content: EURAS International GmbH, Eime, Germany.
All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.
|
|