EURAS System
   EURAS worldwideeuras.com    
EURAS System

C2182DAS 991931010622 / FIMI [20" monitors]

The EURAS repair tip database for professional technicians and service engineers supplies the following faults for C2182DAS / FIMI.

List of fault symptoms:
  • Appliance goes into breaker circuit operation (short circuit protection).
  • No text on LCD display.
  • Failure of F601.
  • Brightness is unstable. Picture flickers.
  • Blurred picture. Smell of burning from the line output stage.
  • Adjustment via software. Interface is unnecessary, cable is sufficient.
  • Error message: HV failure.
  • Flickering picture.
  • Vertical output stage oscillates. Black stripes on picture.
  • Service manual correction.
  • No function - V805.
  • One of the three line pre-power and output stage transistors (V830, V829) has exploded.
  • Spare part information (1).
  • With a 1024x768 resolution and higher, picture becomes blurred.
  • 'No V-sync' message in display.
  • Smoke from PSU and type of diode V614/V12.
  • No picture. Appears after turning up G2 screen without picture content.
  • No function, V806 (IRF730) and V815 (THD400) are defective.
  • Vertical fault.
  • H geometry linearity is compressed on the right side. (service info for FIMI -C2182DAS)
  • Goes irregularly into protection mode - High Voltage Failure.
  • "High Voltage Fail" appears in the display, after various adjustments were shown.
  • Adjustment via software. Interface unnecessary, cable is sufficient with the following configuration.
  • Error message: 'V Sync OFF' (only temporary) then 'H DEFL.Failure', no more functions.
  • AC/DC measurement.
  • Picture is much too small.
  • Occasionally dark, horizontal line in middle of picture occasionally vertical jitter.
  • Convergence very bad in all modes.
  • Demagnetises several times at switch on and otherwise by itself.
  • Smoke from appliance.
  • After some time set in protection mode, error high voltage.
  • Shadows behind text in windows.
  • Technical data.
  • Loss of data in the memory due to noise.
  • V convergence is out statically and cannot be adjusted.
  • Occasionally picture pumps for approx. 1cm.
  • No picture. (C2182DAS FIMI repair tip)
  • Updated software. (FIMI - C2182DAS information)
  • With 1280x1024 resolution menu items of a CAD program are blurred.
  • Error mesage: Vertical out of range.
  • No digital display. Background lighting and adjustment function ok.
  • Picture is blurred in the corners.
  • If the monitor goes into Low-Power mode it can no longer be put back into normal mode. It works again if the mains is switched on and off.
  • HV EHT adjustment.
  • Checking the high voltage part.
  • No digital display. Raster and controls ok.
  • Blurry picture.
  • Läuft nur selten. "Brutzelgeräusch" ist zu hören. Bild zittert.
  • Horizontal sync adjustment.
  • Squeaking noise.
  • Error message: PLL error and no picture.
  • Picture can no longer be focused.
  • Error message: 'V Sync OFF' (only for a short time) then 'H DEFL. Failure'. No further function, PSU ok.
  • Vertical convergence.
  • Monitor does not restart after sleep mode.
  • Blurred.
  • Horizontal width.
  • Picture has a green cast with green flyback lines.
  • Displays 'V out of range' then powers down with red LEDs flashing.
  • Positions of transistors IRF540 and IRF9530 in the sealed high voltage box.
  • Vertical height
  • Vertical shift.
  • Picture size pumps +/-2 mm. Appliance switches off occasionally. "HV-failure" appears in the display.
  • H/V-stage is defective. No picture.
  • Value of resistor (with 1 output transistor) on the main board.
  • Main board is burnt.
  • No start-up. Error message "GEN. Failure" or Horiz.-Failure".
  • Horizontal geometry linearity is compressed on the right side.
  • After switch-on first "PLL error", then "HV error" in display.
  • Ghosting on video.
  • Picture is dark. No CRT drive.
  • Demagnetises approx. 10 times at switch on. (FIMI - C2182DAS information)
  • Excessive brightness.
  • Picture width or entire picture pumps in all resolutions.
  • Picture is very dark or poor in contrast. If the contrast is turned up fully, picture is blurred. (C2182DAS tips)
  • Adjustment via software. Interface is not necessary, cable is sufficient. (C2182DAS tip from FIMI)
  • High voltage failure is displayed, No picture.
  • HV error is displayed. No picture.
  • Failure of R804 (on the degaussing board).
  • HI. VOL. FAILURE message on LCD.
  • Totally inoperative (overscan conditions - resulting in failure of U813).
  • Fine, approx. 1cm wide, dark line which is vertical in the picture and which moves through the picture.
  • Displays 'V out of range' and does not start up.
  • When monitor switched on, CRT is blank and LCD is OFF.
  • No picture. Vertical error in the display. (service info for FIMI -C2182DAS)
  • Dead. V806 (IRF730) and V815 (THD400) are defective.
  • Takes a long time for the picture to appear.
  • Only runs rarely. Sizzling noise. Picture jitter.
  • Variations in brightness over the whole picture area.
  • Adjustment via software. Interface unnecessary, cable is sufficient. (C2182DAS FIMI repair tip)
  • Bad horizontal sync. When using datapath harlequin graphic card.
  • Horizontal stripes in picture. (C2182DAS tip from FIMI)
  • Error message "V-Sync OFF" (only for a short time) then "H DEFL.Failure". No further functions. (service info for FIMI -C2182DAS)
  • White D adjustment.
  • Does not start. "Missing H&V SY.D" appears on display.
  • Occasionally switches off when H sync >37kHz. Smell of burning or smoke, appliance operates.
  • Scanning fault.
  • Spare part information (2).
  • Picture shifted downwards. Bearing control does not function.
  • Code number information (2).
  • Focus setting adjustment.
  • Does not synchronise well.
  • Picture pumps.
  • No picture. "H defl. failure" or "Gen. Failure" appears in the display.
  • High voltage adjustment.
  • Monitor fails in 1280x1024 with video controller 'artist XJS/TI20'.
  • Error message: Horizontal out of range.
  • Test software. (C2182DAS tip from FIMI)
  • V-convergence statically incorrect, cannot be controlled.
  • "Mode not present" display.
  • Switches off after several hours. "General Error" appears in the display. Can be started again immediately.
  • High voltage fails.
  • Picture dark, no picture tube drive.
  • Picture width or the entire picture pumps in all resolutions.
  • After switch-on display becomes lighter and lighter until desktop vanish.
  • Occasionally processor indicates undefined errors.
  • Picture continuously gets rapidly blurred, also brightness varies somewhat.
  • Degaussing starts on itself - with bad results.
  • Occasional general failure.
  • No digital display. Background illumination and adjustment function ok.
  • Switches off after several hours.
  • Horizontal geometry linearity is squashed on the right side.
  • Flashing display.
  • Checking ther high voltage part.
  • Resistance value from the resistor parallel to coil of T803 on the appliance with deflection board and 3 power transistors.
  • Ref of transistor V806 (P8P25), R340 is defective. (Board with the 3 line output stage transistors).
  • Picture gets brighter and brigher until there are flyback lines - after an extended operating time (30-45 min.)
  • No display - all supply-LEDs are on.
  • Bad convergence. (service info for FIMI -C2182DAS)
  • After a few seconds of self-test "General failure" is displayed.
  • Failure of V823-V829-V830 (short circuit and damage of P.W. board).
  • Picture is blurred (very wide vertical lines), resolution perfectly adjustable but still variations in brightness. (fault occurs on BJ95/21" appliances).
  • Error message: Horizontal deflection failure.
  • Monitor fails in 1280 x 1024 with video controller "ARTIST XJS/T120".
  • After approx 5 mins operating time, picture disappears after switching from Dos to Windows (task). "High Voltage Failure" appears in the display.
  • Down control and high voltage output stage (V815 and V806) fail again.
  • 'High voltage fault' appears in the display.
  • Oscillation in the picture. Video board is knock sensitive.
  • Specifications.
  • Only black screen. (C2182DAS tip from FIMI)
  • Does not start. On the display the message "Missing H&V SY.D" appears.
  • Horizontal convergence.
  • Failure of V801.
  • Code number information.
  • Picture disappears shortly (intermittent).
  • Picture changes brightness, not knock sensitive.
  • Picture flickers then only blue and no content. No thermal faults.
  • Horizontal phase.
  • Sporadic brightness variations.
  • Left vertical and top horizontal menu items are blurred, if operated with CAD program 1024x768 and higher.
  • Transistor V815 defective. Lettering reads N414 / THD400. Resistor R922 burnt.
  • Line drive transistor V815 (THD400) and V806 (IRF730) S/C.
  • No function, displays -GEN.FAILURE. (C2182DAS tip from FIMI)
  • FET Pos. no. V818 is burst.
  • Failure of V805/V851/V853 (short circuit).
  • B+ supply voltage adjustment.
  • Display has a deflection fault.
  • Dead.
  • Picture is dark. No picture tube drive. (service info for FIMI -C2182DAS)
  • Picture disappears after some time. No error message in the display.
  • "V-Sync out of range" then "Hi-voltage fail" error in the display.
  • Code number correction.
  • Occasionally picture is not in focus. In DOS mode vertical lines in the left half of the picture.
  • Colour red is blinking.
  • HV setting.
  • Resistor R910 is burnt (parallel to transformer T803, dynamic focus).
  • Vertical convergence is quite wrong and cannot be adjusted. (C2182DAS tips)
  • Part no. info: connection rail between the front and back mains switch.
  • Value of R878.
  • Occasionally appliance switches to standby because self test warns of a vertical fault.
  • No width control due to failure of 6624.
  • Horizontal size varies. Burning smell.
  • Different versions of the HV box.
  • No picture, video output stage does not function.
  • H-linearity is shrunk on the right.
  • Interface cable.
  • No functions.
  • Appliance pumps, no picture. Occasionally at starting up "V out of range" and "Gen Failure" visible in the display. (FIMI - C2182DAS information)
  • Occasionally colour temperature change (knock sensitive).
  • Switches off with 'high voltage fail', if the picture brightness suddenly increases greatly.
  • No start up, displays 'sync missing', 'high voltage fault' or "PLL error".
  • Vertical convergence is incorrect.
  • Dynamic focus is defective. Picture is blurred in the middle.
  • Too little contrast.
  • Vertical convergence is out with regard to static and cannot be adjusted.
  • Picture jitter. Smell from appliance after warming up.
  • No high voltage. No deflection. Switch power supply pumps as a result of a S/C.
  • Replacement for transistor V806 MOTOROLA P8P25 on the deflection board.
  • No function - start voltage V17 at approx. 40V instead of approx. 15..17V.
  • Switches constantly from normal picture size to a small picture, significant E/W fault, picture becomes extremely bright, front keys do not work. Fault arose when focus control was adjusted.
  • Starts normally, then "high volt error" appears in the display.
  • The picture is de-focussed in low frequency VGA-modes.
  • After a short time high voltage failure. Beam current varies.
  • No vertical synchronisation.
  • Error message: H-Failure.
  • Normal picture, however when switching over to other resolutions or similar, it switches off and indicates a high voltage fault in the display.

Tips are coming from EURAS customers, workshops and payed technicians from all over the world. FIMI C2182DAS fails can be better solved.

If FIMI C2182DAS fails, this information will help you. Here you can only see the symptom list, to access remedies, you must register.

With help of this list a solution is found often when FIMI C2182DAS fails.


Additionally to repairtips or service information C2182DAS 991931010622 is linked to 25 components (IC's and/or transformers) in the Tectra database, through which you can identify electrical compatibilities (crossreferences) in appliances.


Chassis information is available (which chassis is built in into C2182DAS 991931010622).

EURAS system also knows 57 appliances having the same chassis as C2182DAS 991931010622 and can easily list them.

For C2182DAS 991931010622 there are 28 compatible appliances known and can be listed.


In the repair discussion pinboard for C2182DAS 991931010622 there are 10 replies to questions asked about 3 different repair problems.
With access to EURAS you can all read them or enter your own questions and get help for C2182DAS from EURAS technicians or other users.

Do you want to see this remedies/cures for repairtips?   Register here for the EURAS System
Please note: access to the EURAS System can be granted only to professional Video/technicians/household electronics repair shops/TV which are authorized for service by a manufacturer, or can prove to be professionally certified to do repairs on electronic appliances. You will be asked for a statement and information accordingly during registration.

If you do not qualify as stated above and you have an appliance that needs technical service, we do recommend you to contact the manufacturer (for example through his website) or go to a professional household/Video/TV electronics repair shop close to you.

Already registered? open C2182DAS FIMI in EURAS

All details on the EURAS System: English | Deutsch | Français | Italiano | Español | Magyarul | Português | Polski | Română | Greek |


Back to EURAS Homepage >> All manufacturers >> FIMI tech tips  












Last updated: 14. Oct 2008 03:39:06 MET, doccode ISO9002AS168EKA200805C EURASMOP

Responsible for the content: EURAS International GmbH, Eime, Germany.
All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.