25D6F / INTERFUNK [TV]
The EURAS repair tip database for professional technicians and service engineers
supplies the following faults for 25D6F / INTERFUNK.
List of fault symptoms:
- When warm UHF channels drift, particularly between channels 33 and 59. (picture attached)
- No contrast.
- E/W correction fault. Picture rounded to centre.
- Switches off by itself. after a few minutes.
- Picture has shifted with approx. 3cm to the right, as if foldover available.
- Contrast and colour will not increase.
- Reduced vertical size.
- Poor contrast, almost negative picture, especially via AV. (service info for INTERFUNK -25D6F)
- Disable hotel mode.
- Dead (intermittently).
- Dead or stuck in standby. (25D6F tips)
- Only black picture and OSD after a while. No sound.
- No functions. Standby LED lit . (with circuit diagram extract)
- Tuning drifts. No TXT.
- Shuts down. after start-up.
- No raster. Possibly sound ok. Standby LED ok. Possibly NICAM LED flashing. (picture attached)
- Switches off after short operation while.
- No function. Standby LED flashes at switch on. No picture. No sound.
- No synch and no text via scart. Ok via HF.
- Impossible to start up from standby. Normally starts up from On/Off switch.
- When TV started up, transistor (S2000AF) instantly burn out.
- Picture is faint and has no vertical synchronization.
- No vertical deflection. Frying noise from PSU.
- Picture collapses to lines, is reduced and drops out after approx. 1 min operation.
- White screen. (picture attached)
- Horizontal tearing. when cold.
- Poor line sync.
- Intermittently switches to standby when on for few minutes; then OK when switched back on; click from speakers when switching off. (with circuit diagram extract)
- Switches to standby. after a while. No start-up. when cold. (+ extract of circuit diagram)
- No audio. OK via SCART . Switches to standby (after a few minutes).
- Vertical amplitude alignment adjustment.
- Dark screen. at start-up. (picture attached)
- Switches to protection mode.
- When cold, switches off almost immediately; symptom gradually improves as appliance gets warmer. If brightness is turned down stops switching off. (part of circuit diagram displayed) (25D6F tip from INTERFUNK)
- Setting U1.
- No colour. No contrast. Picture has shifted horizontally by 5cm towards left-hand side.
- Picture jumps from normal program to noise or to another program.
- Power supply transistor (BUF405A) blown after approx 1½ hrs.
- Green picture. Flyback lines. (extract of circuit diagram attached)
- In cold conditions, PSU triggers. Attempts to start, but it blocks.
- Slow start-up.
- Picture is very blurred and vertical is not synchronised. With a VCR connected to scart picture is synchronised and is ok.
- Dead. Squealing from PSU. (part of circuit diagram displayed)
- Low contrast.
- Low power supply voltages which increase when line transformer is disconnected.
- AFC adjustment.
- Almost negative picture.
- Picture pulls horizontally. OK when warm.
- TV does not function. 50V on 120V line, power supply secondaries OK, line transformer secondaries OK, power supply TEA has been changed, standby light is off, power supply BU oscillograms incorrect.
- Failure of line drive transistor VK01. (25D6F tip from INTERFUNK)
- Horizontal amplitude alignment adjustment.
- Picture has shifted to the left and is black and white. No sound. OSD is positioned correctly, 8362 has been changed. (25D6F tips)
- Screen has white line across.
- Vertical position alignment adjustment. (INTERFUNK - 25D6F information)
- G2 and colour temperature alignment adjustment.
- U1 voltage alignment adjustment.
- Squealing from PSU (after start-up). Excessive horizontal size. (picture attached) (INTERFUNK - 25D6F information)
- Picture adjustment is not done in manual search of channels B and C. Sound adjustment ok.
- No sound in the tuner, picture ok. After a moment TV stops as if there was no programme. Does not stop on channels in channel search. Sound ok in scart. (service info for INTERFUNK -25D6F)
- Teletext decoder alignment. (service info for INTERFUNK -25D6F)
- Interference at switch-off.
- 1 pulse then dead.
- Insufficient picture height.
- Horizontal line. in the centre. (with circuit diagram extract)
- Bright picture with flyback lines after 30 mins. (25D6F tip from INTERFUNK)
- No colour and no contrast (commands do not respond). Display OK.
- Picture tube board 5858 2050 does not fit into the chassis version with the connection plugs.
- Poor contrast via AV, TV-picture also somehow sludgy.
- Appliance breaks down.
- Interference noise in NICAM sound during SECAM-L reception. (by very high volume set-up).
- When using a NINTENDO console, TV does not return to TV mode after putting NINTENDO console into standby.
- Goes into automatic search after operating for a few mins. Channel buttons blocked on the RC. (INTERFUNK - 25D6F information)
- C033 (10uF) runs hot.
- Bright picture. Flyback lines.
- Setting the focus.
- Horizontal roll.
- Adjusting the sound.
- Text processor switches to TEST mode.
- No picture. OSD OK . (picture attached)
- Enter service mode.
- No vertical deflection.
- No start-up (intermittently).
- Trips.
- Sound calibration alignment - Multinorm Module.
- Resistor RK31 has changed colour.
- AGC adjustment.
- Poor vertical linearity.
- Picture and sound muted when standby selected.
- 4cm band at the top and bottom of the screen and picture jumps.
- Colour tint in screen centre after switch-off.
- When sunlight falls on receiver, remote control does not function.
- No picture.
- PSU starts up briefly then no functions.
- TV starts up when cold and cuts out after 20 secs then power supply pulsates. Occasionally functions for 1 hour.
- Faulty PSU.
- If contrast is at maximum, when bright advertisments come up, TV turns off and switches to standby.
- Fails after 3/4 of an hour, no standby LED after replacing line output transformer. Crackling in loudspeaker at switch off. After switch off runs again for only approx 3/4 of an hour.
- No reception in cable network.
- Focus alignment adjustment.
- Dull picture and lack of luminance, chroma OK.
- After line transformer has been changed high voltage flash overs in the focus regulator.
- Picture does not hold.
- Power supply doesn't start up, after restart with mains switch functions OK.
- Enable Hotel mode.
- Screen becomes whiter and whiter. Appliance switches off and then goes to standby. Startup and sound are OK. (25D6F tip from INTERFUNK)
- Reduced horizontal size. intermittently. (25D6F INTERFUNK repair tip)
- Horizontal line, picture dark in AV and can not be switched further.
- Short white lines run through the picture. Background has no picture content. Neither TV sound nor noise can be heard. Picture and sound occur after 10 mins
- Muted audio. intermittently.
- Setting the horizontal amplitude.
- Tries to start up but switches off after a sec.
- Poor audio. No colour. Picture shifted to the left.
- Bright picture. Flyback lines. Switches off by itself. after a few seconds.
- When cold, TDA2653A burns out. (with circuit diagram extract)
- Stuck in standby. (picture attached)
- Power supply collapses. Power supply ok when 26V raster disconnected. (25D6F tip from INTERFUNK)
- Horizontal line.
- Horizontal and vertical holds of both syncs are lost. (25D6F tips)
- Switches to standby (intermittently). (extract of circuit diagram attached)
- Picture crackling at switch on.
- Resistor R050 in PSU fails.
- Numerous defects in power supply.
- Does not display SECAM standard. Operates ok in SECAM via scart. Functions ok in PAL, selection of standard 2 or 3 ok.
- Switches to standby, can be restarted again. No fault when TXT is activated.
- Does not switch on from standby with RC. Other functions are OK. May occur after a few days. (extract of circuit diagram attached)
- Line driver TSVK01 (BC327-25) fails immediately. (25D6F tips)
- Diode VK03 (ZPY 5.6V) is defective.
- AFC alignment check.
- Horizontal output stage fails immediately. (with circuit diagram extract) (25D6F INTERFUNK repair tip)
- Impossible to switch back on again after standby.
- Dead. Standby LED ok. Possibly NICAM LED flashing. Possibly sound ok. (part of circuit diagram displayed)
- Picture loss after 30-40 mins. Audio OK.
- No UHF mode. OK in VHF mode.
- Dim picture. after warm-up.
- No audio. Picture OK .
- No synchronisation. Audio and OSD OK . (25D6F tip from INTERFUNK)
- Standby line whistles. (INTERFUNK - 25D6F information)
- Appliance is dead. when switching on the standby LED flashes once.
- Stuck in standby. Front LED ok at switch on, then standby LED. Front LED and stereo LED flicker successively when tuning in a channel with RC or with front controls. (with circuit diagram extract)
- Loud whistling of the HT when warm.
- Afterglow at switch off.
- Tripping or pulsing. (25D6F tip from INTERFUNK)
- In automatic search channels B and C are not recognised or stored. (25D6F tip from INTERFUNK)
- Buzz in audio.
- Wavy vertical lines, sometimes very obvious, sometimes faint. Noise from low voltage power supply. (picture attached)
- No functions.
- No start up. When switching off by the switch the front LED lights up for a short time. Restricted lamp and sound present before cut off. Nothing if you insist. (service info for INTERFUNK -25D6F)
- After replacing capacitor C033 it fails again within a few months.
- No start-up. (+ extract of circuit diagram)
- Reduced horizontal size.
- PSU pulsates.
- Coloured menu.
- Line tearing. after a few minutes. Switches to standby. (+ extract of circuit diagram) (25D6F tips)
- Blows fuse. intermittently.
- DD01 (TDA8360/62) is defective.
- Low contrast. Low brightness.
- When selecting other than page 100, text comes on with page 888 for eg. Only on some channels.
- EHT appears briefly and PSU cuts out.
- Vertical collapse. (with circuit diagram extract)
- No audio.
Tips are coming from EURAS customers, workshops and payed technicians from all over the world. INTERFUNK 25D6F fails can be better solved. If INTERFUNK 25D6F fails, this information will help you. Here you can only see the symptom list, to access remedies, you must register. With help of this list a solution is found often when INTERFUNK 25D6F fails.
|
Additionally to repairtips or service information 25D6F is linked to 158 components (IC's and/or transformers) in the Tectra
database, through which you can identify electrical compatibilities (crossreferences) in
appliances.
|
Chassis information is available (which chassis is built in into 25D6F ).
EURAS system also knows 656 appliances having the same chassis as 25D6F and can easily list them.
In the repair discussion pinboard for 25D6F there are 10 replies to questions asked about 17 different repair problems. With access to EURAS you can all read them or enter your own questions and get help for 25D6F from EURAS technicians or other users.
Do want to see this remedies/cures for repairtips? Register here for the EURAS System
Already registered? open 25D6F INTERFUNK in EURAS
All details on the EURAS System: English |
Deutsch |
Français |
Italiano |
Español |
Magyarul |
Português |
Polski |
Română |
Greek |
Back to EURAS Homepage >>
All manufacturers >>
INTERFUNK
tech tips