CTV28100ST APK000 / ITT [TV 70-74 (66-70) cm picture]

The EURAS repair tip database for professional technicians and service engineers supplies the following faults for CTV28100ST / ITT.

List of fault symptoms:
  • Picture is only visible in the top fourth.
  • Picture too small and slight pumping according to picture content.
  • Standby OK, pumps with a whistle after switch on.
  • Switches off by itself. LED blinks .
  • Two vertical stripes on the left and right sides by bright picture via scart. (CTV28100ST tips)
  • Slow start-up.
  • How to reprogramm the appliance so thet it can be switched on via he mains switch without going via standby. (CTV28100ST tip from ITT)
  • Bright picture. Flyback lines. Shuts down. after a few seconds.
  • Picture becomes bright. Flyback stripes, then protective circuit switches on. (service info for ITT -CTV28100ST)
  • Switches to protection mode.
  • Red LED is lit. LED switches off briefly when trying to start via RC, slight oscillation audible, then LED red again.
  • Picture size changes with beam current and slight E/W distortion.
  • E/W fault. Picture too large with slight bowing, format switching ok.
  • Switching transistor S/C between collector and emitter, after 3 secs. (ITT - CTV28100ST information)
  • No picture via AV1, ok via tuner and AV2.
  • Noises from PSU.
  • No vertical deflection.
  • Switches off after 10 sec. Standby LED flashes 3 times, 3 sek. pause, then LED flashes again 3 times.
  • Picture folded over at the top. Bright lines in the picture.
  • Line output stage transistor (2SC5331) and R536 (6R8/1W) are defective. (service info for ITT -CTV28100ST)
  • No picture. Audio OK . (service info for ITT -CTV28100ST)
  • E/W fault.
  • Horizontal output transistor fails repeatedly.
  • Oscialltes at start up briefly, switches then immediately off.
  • Clock display runs erratically in standby.
  • PSU bleeps. (CTV28100ST tip from ITT)
  • Line output stage transistor fails immediately after switch on.
  • Enter service mode.
  • Black screen. after a few minutes. Audio OK .
  • No functions. PSU pulsates.
  • PSU ticks. LED blinks. (ITT - CTV28100ST information)
  • No picture content / blue picture. Display and TXT present. When Blue Picture option in the MENU is OFF, then the picture is white. (service info for ITT -CTV28100ST)
  • Reduced horizontal deflection. Reduced vertical deflection.
  • Reduced horizontal amplitude after switch-on for approx. 5-8 secs., with slight E/W effect, then horizontal amplitude jumps to the right value. (ITT - CTV28100ST information)
  • Audio rattles.
  • Protection mode activated.
  • Picture is too large, there is no contrast.
  • No RC functions.
  • Switches to standby. after a few seconds. Standby LED flashes .
  • Horizontal deflection is too low. E/W fault.
  • Intermittently no picture. Picture disappears slowly, is then completely dark.
  • Picture is too small both horizontally and vertically. (CTV28100ST ITT repair tip)
  • No function. All LED pump.
  • Line transistor fails after two days.
  • Dead. (ITT - CTV28100ST information)
  • Excessive horizontal size. No E/W correction.
  • Picture too bright. Menu can be called up, picture content cannot be recognised.
  • E/W error, picture too wide, format switching does not function.

With help of this list a solution is found often when ITT CTV28100ST fails.


Additionally to repairtips or service information CTV28100ST APK000 is linked to 26 components (IC's and/or transformers) in the Tectra database, through which you can identify electrical compatibilities (crossreferences) in appliances.


Chassis information is available (which chassis is built in into CTV28100ST APK000).

EURAS system also knows 29 appliances having the same chassis as CTV28100ST APK000 and can easily list them.

In the repair discussion pinboard for CTV28100ST APK000 there are 25 replies to questions asked about 5 different repair problems.
With access to EURAS you can all read them or enter your own questions and get help for CTV28100ST from EURAS technicians or other users.

Do you want to see this remedies/cures for repairtips?   Register here for the EURAS System
Please note: access to the EURAS System can be granted only to professional Video/TV/technicians/household electronics repair shops which are authorized for service by a manufacturer, or can prove to be professionally certified to do repairs on electronic appliances. You will be asked for a statement and information accordingly during registration.

If you do not qualify as stated above and you have an appliance that needs technical service, we do recommend you to contact the manufacturer (for example through his website) or go to a professional Video/household/TV electronics repair shop close to you.

Already registered? open CTV28100ST ITT in EURAS

All details on the EURAS System: English | Deutsch | Français | Italiano | Español | Magyarul | Português | Polski | Română | Greek |


Back to EURAS Homepage >> All manufacturers >> ITT tech tips  












Last updated: 01. Dec 2008 19:23:17 MET, doccode ISO9002AS168EKA200805C EURASMOP

Responsible for the content: EURAS International GmbH, Eime, Germany.
All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.