19TEC1 / KTV [TV]

The EURAS repair tip database for professional technicians and service engineers supplies the following faults for 19TEC1 / KTV.

List of fault symptoms:
  • Dead. No B+ to base of Q404. (19TEC1 tips)
  • Dead.
  • Shuts down.
  • No colour.
  • Dead. relay chattered
  • Dead. Relay clicks.
  • Distorted audio and could be thermal.
  • Reduced vertical deflection.
  • Snow in picture.
  • Pix had fringing around images. Q404 gets hot. Pulls in from sides. Goes dark. Smoke.
  • Every 2 hrs - loss of colour; loss of h-sync; switches on/off.
  • H-driver transistor T401 runs hot, causing Q404 to S/C.
  • Bars, jail type on left
  • Vertical sweep down 1/2 inch from top
  • H.o.t. repeat failure. T401 horiz drive xfrmr runs hot
  • Dead. F801 open. Storm damage.
  • Dead, storm damage. Fuses OK.

With this service information, you may repair KTV 19TEC1 faster/better when it fails.

When KTV 19TEC1 fails , these symptoms are known and EURAS knows the remedy/solution.

Tips are coming from EURAS customers, workshops and payed technicians from all over the world. KTV 19TEC1 fails can be better solved.

If KTV 19TEC1 fails, this information will help you. Here you can only see the symptom list, to access remedies, you must register.

With help of this list a solution is found often when KTV 19TEC1 fails.

Chassis information is available (which chassis is built in into 19TEC1 ).

EURAS system also knows 3 appliances having the same chassis as 19TEC1 and can easily list them.

Do you want to see this remedies/cures for repairtips?   Register here for the EURAS System
Please note: access to the EURAS System can be granted only to professional TV/household electronics repair shops/Video/technicians which are authorized for service by a manufacturer, or can prove to be professionally certified to do repairs on electronic appliances. You will be asked for a statement and information accordingly during registration.

If you do not qualify as stated above and you have an appliance that needs technical service, we do recommend you to contact the manufacturer (for example through his website) or go to a professional TV/household/Video electronics repair shop close to you.

Already registered? open 19TEC1 KTV in EURAS

All details on the EURAS System: English | Deutsch | Français | Italiano | Español | Magyarul | Português | Polski | Română | Greek |


Back to EURAS Homepage >> All manufacturers >> KTV tech tips  












Last updated: 01. Dec 2008 19:44:32 MET, doccode ISO9002AS168EKA200805C EURASMOP

Responsible for the content: EURAS International GmbH, Eime, Germany.
All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.