 |
CTV1401TEXT / NIKKAI [TV 36/37 (34-36) cm picture]
The EURAS repair tip database for professional technicians and service engineers
supplies the following faults for CTV1401TEXT / NIKKAI.
List of fault symptoms:
- Field sync is missing. (service info for NIKKAI -CTV1401TEXT)
- Synchronisation is missing or intermittently missing.
- Raster is blank only flyback lines present.
- Poor line sync and intermittent colour.
- Reduced field scan with foldover.
- Line oscillator does not function.
- TXT lines.
- Set does not start up.
- VIF alignment.
- Stuck in standby.
- Vertical foldover at top and bottom.
- Horizontal shift fault.
- Stuck on channel 1. No signal intermittently. (service info for NIKKAI -CTV1401TEXT)
- Intermittently changes channel by itself. Volume varies and goes to standby.
- Occasionally appliance switches off.
- Dead.
- Blank raster.
- Frame oscillator does not function.
- Picture tube is not lit.
- Channel display number does not correspond to channel.
- Blanking problems. (service info for NIKKAI -CTV1401TEXT)
- Horizontal centre adjustment.
- Outside of picture is wavy (depending on beam current).
- Ballooning effect.
- Intermittent frame bounce.
- Appliance trips when changing channel.
- Inadequate colour identification.
- Incorrect line speed.
- Convergence adjustment.
- Displayed channel no. does not match the channel.
- Height is reduced and picture foldover.
- No vertical deflection.
- Insufficient height or the height varies.
- Intermittently RCU does not function.
- Vertical jitter.
- Dark picture.
- No raster. Sound OK.
- Only snow, no display.
- The appliance has a dark picture.
- When volume increased row of dots indicate volume still at minimum.
- Video processor oscillation frequency adjustment.
- RF AGC adjustment.
- No picture.
- Appliance trips when warm. (CTV1401TEXT tips)
- Reduced vertical size.
- Width is reduced and picture is faint.
- Field sync fault.
- Dead or intermittently dead.
- Raster is green with flyback lines.
- Reduced horizontal size.
- PAL matrix phase adjustment.
- Horizontal oscillation alignment.
- No contrast.
- Incorrect frame linearity.
- Various symptoms:- no tuning, no sound, full sound, dead set etc. (NIKKAI - CTV1401TEXT information)
- Ghosting effect.
- Picture snowy looks like a tuner fault.
- Channels cannot be tuned in or stored.
- Stripes over the picture. (NIKKAI - CTV1401TEXT information)
- Frame collapse or intermittent frame collapse. (CTV1401TEXT NIKKAI repair tip)
- EHT brushes or arcs.
- The appliance is dead (tripping). (CTV1401TEXT tip from NIKKAI)
- No colour.
- Red, blue or green luminance signal is missing.
- The output of the power supply falls slowly until the point where the field cramp becomes apparent.
- "O" symbols with tails fill screen on TXT; bar for analogue settings flash.
- Reference oscillator adjustment.
- Signal is intermittent. (service info for NIKKAI -CTV1401TEXT)
- Poor picture quality, smearing, milkiness, glistening on peak whites or insufficient brightness.
- Striations and flyback lines. (CTV1401TEXT NIKKAI repair tip)
- Channel changes at random.
- Chopper transistor TR13 S/C.
- White balance adjustment.
- Vertical collapse.
- Trips.
- Field bounce or jittering.
- Infra-red receiver does not function.
- Vertical circuit adjustment.
- No audio. No picture.
- PAL matrix amplitude adjustment.
- There was a snowy raster but no sound or channel indicator illumination.
- Field blanked from 1 to 3 inches at top of screen.
- Reverting to channel 1.
- Snowy picture and field roll.
- Intermittent loss of signals and randomly unhappy about channel three selection.
- Picture has moved to one side.
- Picture is grainy and sound noisy.
- Switched mode power supply trips when warm.
- Stops tripping if C811 PSU is disconnected.
- Sound and vision (drop out, signal missing).
- Dead. PSU pulses.
- Tripping (intermittently).
- Excessive brightness. Flyback lines. (NIKKAI - CTV1401TEXT information)
- Unstable picture, line hold control has no effect.
- Tuning drifts (intermittently).
- Brightness fault.
- Field roll with a snowy picture.
- Tuner only memorises stations with even numbers.
- Field collapse, no sound.
- Vertical size adjustment.
- Focus adjustment.
- Intermittently dead.
- Intermittent manual channel change.
- Frame synchronisation poor.
- LEDs not lit or only partially lit. (NIKKAI - CTV1401TEXT information)
- Intermttently powers down.
- Focus problems.
- Low width and a dim picture, improving slowly over about an hour. (service info for NIKKAI -CTV1401TEXT)
- Raster is blank with flyback lines.
- Blank raster. Audio OK .
- Frame collapse with no sound.
- Blank raster but sound and on screen display ok.
- Goes back to channel 1.
- Protection circuit trips too early.
- EHT missing, line timebase ok.
When NIKKAI CTV1401TEXT fails , these symptoms are known and EURAS knows the remedy/solution.
Tips are coming from EURAS customers, workshops and payed technicians from all over the world. NIKKAI CTV1401TEXT fails can be better solved. If NIKKAI CTV1401TEXT fails, this information will help you. Here you can only see the symptom list, to access remedies, you must register. With help of this list a solution is found often when NIKKAI CTV1401TEXT fails.
Chassis information is available (which chassis is built in into CTV1401TEXT ).
EURAS system also knows 39 appliances having the same chassis as CTV1401TEXT and can easily list them.
For CTV1401TEXT there are 11 compatible appliances known and can be listed.
Do you want to see this remedies/cures for repairtips? Register here for the EURAS System Please note: access to the EURAS System can be granted only to professional
household electronics repair shops/TV/Video/technicians which are
authorized for service by a manufacturer, or can prove to be professionally
certified to do repairs on electronic appliances. You will be asked for a
statement and information accordingly during registration.
If you do not qualify as stated above and you have an appliance that needs
technical service, we do recommend you to contact the manufacturer (for
example through his website) or go to a professional Video/TV/household
electronics repair shop close to you.
Already registered? open CTV1401TEXT NIKKAI in EURAS
All details on the EURAS System: English |
Deutsch |
Français |
Italiano |
Español |
Magyarul |
Português |
Polski |
Română |
Greek |
Back to EURAS Homepage >>
All manufacturers >>
NIKKAI
tech tips
Last updated: 11. Oct 2008 00:43:21 MET, doccode ISO9002AS168EKA200805C EURASMOP
Responsible for the content: EURAS International GmbH, Eime, Germany.
All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.
|
|