CS8826 ICC335 / PATHEMARCONI [TV]
The EURAS repair tip database for professional technicians and service engineers
supplies the following faults for CS8826 / PATHEMARCONI.
List of fault symptoms:
- Trapezoid picture.
- No sound or picture. Display ok.
- FBT whistles and BU 208D blows with BU806.
- Variation of frame stability or intermittent pulsating.
- Picture is shifted to bottom of screen. (PATHEMARCONI - CS8826 information)
- No regulation of TP05.
- Insufficient line amplitude.
- Remains in standby. No regulation. 110V ok.
- No start-up.
- No start up. Stand-by LED is on.
- Line BU cuts out after a week or more. 143V ok, CTV works normally.
- Weak distorted sound. Fault is on board AM3201.
- E/W cushion problem, LG02 becomes burning hot. (CS8826 tips)
- Value of RP14.
- E/W pincushion cannot be regulated correctly.
- The whole of the screen is purple.
- Insufficient width. Raster fault.
- Scarcely any brightness.
- No muting.
- The height and width are not sufficient. Power supply is defective.
- LG02 heats up. U4 At 250V. Everything has been changed.
- Blurry picture.
- Display flashes, no HT on tube. When unsoldering pin 7 from flyback transformer, horizontal white bar and frying noise.
- Fuse FP01 blows after one or two days.
- Severe echo on picture.
- The picture can hardly be seen. The signal is incorrect on 23/MTS4000.
- No light.
- Scanning problem. Vertical line on the screen. Voltages: U1 145V, U2 12.5V, U3 18V, U4 85V, U5 7V. After 5 minutes, smoke from LG02.
- Noise from line transformer and flyback lines.
- BU208D only holds for 2 months.
- How to store channels. (CS8826 tip from PATHEMARCONI)
- Reduced picture then total fault with display. After changing TL02 and RP14, functions for 3 hrs then TL02 blows again with FP02. RP14 ok.
- No function and no display. The very high voltage starts up by short circuiting TP21.
- No E/W correction. Picture is too large.
- Picture becomes dark or occasionally purple.
- Lacks width and flyback line.
- No sound at all but the BF amplifier is correct.
- TL01 blows.
- Intermittently dark screen, also in RGB. Sound ok. (CS8826 tip from PATHEMARCONI)
- The appliance starts up one time out of three. If the start up is ok, the line transformer crackles and RL25 burns out at once.
- No 24V voltage or picture at the bottom of the screen. (CS8826 tip from PATHEMARCONI)
- Line amplitude is too weak and the lines are wavy.
- Stuck in standby.
- PSU and display are pulsating.
- No vertical scanning. Visible line scanning.
- Front panel LED flickers at switch on.
- Value of safety resistor RF14 on HT line.
- The top part of the picture has shifted.
- Interference lines at top of screen.
- No vertical deflection.
- Horizontal tearing only in scart. IV03, IV03, CV63 have been replaced. E/W cushions are ok. The fault occurs especially if the picture contains a lot of white.
- No 7V (U5), HF or display.
- RL 18 (3.9K) burns out after working for a few seconds. THT starts up, but however is insufficient.
- Very bright screen with flyback lines after 5 minutes operation.
- TL02 (BU208D) has a short circuit (double pulse). (CS8826 tips)
- No audio. No picture.
- E/W fault.
- Vertical shift and slight foldover at top of picture. Goes into safety when vertical adjustment and alignment are used. (CS8826 PATHEMARCONI repair tip)
- The appliance hums and the picture shrinks.
- The appliance hums and the picture shrinks. (CS8826 PATHEMARCONI repair tip)
- No EHT but display present.
- Flyback transformer whistles. Line- and raster scanning sometimes fail.
- Height and width fault. The U1 voltage is incorrect.
- Line spacing at top of screen which goes downwards when TV is left on.
- No EHT, voltages ok. No drive on base of line transistor.
- Raster problem. Picture shifted to the top of the screen. Poor vertical synchronisation. ESM 740 ok, 21V ok, DL20 ok. It is impossible to adjust the appliance.
- Picture with one predominant colour even in black and white.
- Video is very poor. Picture is hardly visible.
- How to change a deflector which is glued in place on 4 points on the CRT. (PATHEMARCONI - CS8826 information)
- Red colour appears faintly for an instant. Flyback lines.
- Picture out of alignment towards the top.
- No regulation.
- Vertical interference bands appear on both sides of the screen.
- No function, no display. (CS8826 tip from PATHEMARCONI)
- Stereo models with amplifier card with transistors are very weak on a single output. Control must be at max to just to be able to hear. Audio outputs are ok on scart socket.
- No sound or picture. EHT is correct.
- Green screen and flyback line.
- No picture but rainbow on both sides of screen. Sound ok.
- Line desynchronisation of the picture after a moment.
- Excessive height. Amplifier can be adjusted but vertical alignment does not allow correct positioning of picture in order to increase its size.
- Channel storage inactive. Keeps on returning to the previously adjusted channel.
- Picture folds down. Slight width fault.
- Blue stain at bottom left of screen. Impossible to remove by external degaussing.
- The picture shifts towards the right.
- No Y signal.
- No sound or picture. Scanning and display are ok.
- Picture content does not change when changing channel.
- Display and power supply pulsate.
- When light and contrast are high the picture is still too dark. When they are at a middle value, there is no picture.
- Interwoven lines at the top of the screen.
- Picture is too wide. No East/West correction.
- When the G2 is pressed an E/W fault occurs.
- No vertical scanning. TED01 makes a whistling noise. Smoke coming from a coil with a core on the FBT.
- No picture or snow. Black screen. Sound OK. Everything OK when connecting a VCR via scart.
- Little or no video.
- Brightness and contrast are weak. Crushing on peak whites.
- Remains in stand by. RP14 is defective.
- The picture shifts towards the top of the screen.
- Fuse blows after 1 or 2 days.
- E/W cushion problem. (CS8826 tip from PATHEMARCONI)
- Eliminating a possible BF humming.
- Panel faults. The functions are the wrong way round, eg sound instead of light. After replacing the IC, everything is ok but functions at maximum for 2 months.
- Goes into protection every second.
- Occasionally no sound or picture and the memory is erased. The RAM functions correctly. (CS8826 tip from PATHEMARCONI)
- Incorrect line centering and there is a black band on the right of the screen.
- Insufficient width with flyback lines.
- No picture or sound. Display ok. (CS8826 tips)
- 1400V on line BU which blows after a few secs.
- Appliance will not start up. Stand by light is on.
- The picture is dark and faded.
- The raster occasionally cuts out.
- TL02 (BU208D) and H8 = 1300v have a short. No 1000V voltage.
- Line BU blows at start up. E/W, TDA 4610 OK.
- Poor raster synchronisation.
- No 24V or picture at the bottom of the screen.
- Insufficient E/W correction.
- The picture flickers.
- TP01 (BU807) becomes hot and shorts.
- Flyback lines and the screen is red.
- After repositioning of frame, picture is shifted towards bottom with excessive line width. Black bars on picture. (service info for PATHEMARCONI -CS8826)
- TP01 BU807 heats up and short circuits.
- Severe hum in loudspeaker during a programme and via scart. Voltages and loudspeakers ok.
- No sound or picture. Very high voltage is correct.
- When switched on picture is half the size vertically, small black lines over the whole of the screen then little by little everything returns to normal in about one min.
- All the secondary voltages of the line stage transformer are lower than normal.
- Sound is ok. No picture, tube filament is not supplied with power.
- Complete shift towards bottom of frame. No picture. When RL52 is removed, reduced picture at bottom of screen.
- LG02 heats up. Picture OK. (PATHEMARCONI - CS8826 information)
- Black bar at bottom of screen.
- No picture at the top part of the screen.
- There are traces of red, but no real red colour.
- The channels run through backwards.
- PSU pulsates.
- Noisy signal in LF.
- The appliance is locked in stand-by.
- White screen with flyback lines. FBT ok, smoke from RP17 in 21V. (service info for PATHEMARCONI -CS8826)
- No contrast or light.
- E/W fault. PG01 MINI. PG02, PG03 do not function. PG01 in normal position. Power supply trips. Abnormal voltage on TDA4610 pin 3 (25V instead of 9.5V).
- Picture correct but shifted towards top of screen. Impossible to correct with vertical position control. Picture compression when insisting on using this control and 5cm missing at bottom of screen.
- The picture amplitude is too high.
- Display flickers at start up. FBT tries to establish itself but trips regularly. Fault seems to be caused by incorrect vertical sync. FBT ok.
- Vertical scanning is defective. Scanning on half of the screen. Synchronisation is defective.
- The appliance cuts out. Half of the picture appears if the safety is mode is removed.
- Black bar at the bottom of the picture and unstable raster.
- Picture with long horizontal streaks according to the content.
- Screen is very blurred with a rainbow effect but without picture. Frame line scans to the outside of the screen.
- The appliance goes into safety mode.
- Little contrast and light. (CS8826 PATHEMARCONI repair tip)
- The screen is multi-coloured and the quality is incorrect.
- Very bright horizontal bar measuring a few cms with sharp whistling.
- The sound hums if the low pitch is raised.
- Shrill noise and unstable raster.
- Varicap voltage does not vary and remains at 33V. (CS8826 tip from PATHEMARCONI)
- Safety resistor RL51 burns and resistor (39R/2W) gets very hot.
- Green screen and flyback line.
- The battery power supply.
- E/W fault. EHT tripping.
- Variation of brightness everywhere but on the test pattern. (PATHEMARCONI - CS8826 information)
- Model C63 PMC4. Inverted function of keyboard keys. There is sound in the place of search. Replace IC HD44860 A27.
- The appliance does not work in LL. (CS8826 PATHEMARCONI repair tip)
- Secondary voltage and EHT low. HT voltage pulsates quickly, slight picture appears, EHT ok, BU command ok, without a load
pulsating follows when loaded. At start up RP14 and DG05 are defective.
- E/W cushion fault. PG01, PG02 and PG03 do not work.
- The top part of the picture is too bright.
- FP02 blows, TP18 defective. If you under supply TV whistles and U3 (21V) = 34V. No BU base command signal.
- BU208D and RP14 blown at switch on.
- Height and width fault and there is no adjustment possible.
- RP14 burnt and B208D defective. RP14 is defective.
- E/W pincushion distortion.
- Transistor TP01 (BU806) overheats. Defective in 1 hr, however 145V ok and regulation seems ok.
- Insufficient line amplitude. Picture bleeding at top.
- Correct operation but the top half of the picture is fuzzy after a divergence of the colour beams.
- Difficulties tuning channels. Dotted chroma and sound is poor and low. Ok in scart. (PATHEMARCONI - CS8826 information)
- PR1 scrolls continually on display. No sound or picture but brightness OK. No RCU or control panel functions.
- E/W amplifier problem. Coil heats up extremely. When TDA4610 is changed line amplitude is normal and LG02 does not heat up.
- Harsh noise and the rasters are unstable.
- Noise signal in low frequency.
- The line amplitude is too weak and the lines are wavy.
- The screen is white.
- Picture shifts upwards in the screen.
- Lack of brightness. (CS8826 PATHEMARCONI repair tip)
- Sound not synchronized with picture. (CS8826 tip from PATHEMARCONI)
- Line centralization is incorrect and black bar on right side of screen.
- White screen with flyback lines. Sound is correct.
- BU208D goes into short circuit. The display on the front flashes. The FBT, CL12, CL03 and the BU806 have been changed.
- The transformer VHT whistles. Intermittent line and raster scanning.
- No picture scanning.
- RP14 and BU 208 D blow at start up after operating normally for a fortnight.
- The screen is continuously scanned.
- Torn picture at the top and bottom parts of the screen.
- E/W pincushion problem. LG02 gets burning hot.
- The appliance will not start up.
- Tuning problem.
- No contrast possible.
- RP14 cuts out occasionally.
- Faulty characters/segments on display.
- No contrast. (CS8826 tip from PATHEMARCONI)
- The FP02 fuse blows at switch on and TP01 (BU806) short circuits. TP01/02/04/05/06 and DPT42/43/12 have been changed. Same fault occurs and occasionally the TV starts up well.
- At switch on channel no. appears but no HT noise. It takes approx 30 secs for sound and picture to come. Then everything is ok.
- Continuous noise for approx one hour. Everything else ok, brightness, contrast, etc. Noise is strong enough to disturb listening.
- Irregular white band in middle of screen. EHT whistling.
- Two horizontal zones moving slowly (as if connected to a mains induction) and which produce a Venetian blind effect.
- Variation of the shade.
Tips are coming from EURAS customers, workshops and payed technicians from all over the world. PATHEMARCONI CS8826 fails can be better solved. If PATHEMARCONI CS8826 fails, this information will help you. Here you can only see the symptom list, to access remedies, you must register. With help of this list a solution is found often when PATHEMARCONI CS8826 fails.
|
Additionally to repairtips or service information CS8826 ICC335 is linked to 21 components (IC's and/or transformers) in the Tectra
database, through which you can identify electrical compatibilities (crossreferences) in
appliances.
|
Chassis information is available (which chassis is built in into CS8826 ICC335).
EURAS system also knows 47 appliances having the same chassis as CS8826 ICC335 and can easily list them.
For CS8826 ICC335 there are 2 compatible appliances known and can be listed.
Do you want to see this remedies/cures for repairtips? Register here for the EURAS System Please note: access to the EURAS System can be granted only to professional
technicians/TV/Video/household electronics repair shops which are
authorized for service by a manufacturer, or can prove to be professionally
certified to do repairs on electronic appliances. You will be asked for a
statement and information accordingly during registration.
If you do not qualify as stated above and you have an appliance that needs
technical service, we do recommend you to contact the manufacturer (for
example through his website) or go to a professional household/Video/TV
electronics repair shop close to you.
Already registered? open CS8826 PATHEMARCONI in EURAS
All details on the EURAS System: English |
Deutsch |
Français |
Italiano |
Español |
Magyarul |
Português |
Polski |
Română |
Greek |
Back to EURAS Homepage >>
All manufacturers >>
PATHEMARCONI
tech tips
Last updated: 16. Oct 2008 05:55:45 MET, doccode ISO9002AS168EKA200805C EURASMOP
Responsible for the content: EURAS International GmbH, Eime, Germany.
All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.
|
|