List of fault symptoms:
  • White balance adjustment.
  • Dark picture.
  • Flyback lines appears when brightness increased.
  • Reduced vertical size. Vertical foldover. when cold.
  • Horizontal line.
  • Black screen. after a few seconds.
  • +B voltage is 160V instead 145V.
  • Tripping at switch-on. Popping noise from speakers.
  • No REC.
  • Switches to standby. intermittently. No start-up from standby. intermittently.
  • Not storing programme data.
  • Cracking noise in standby.
  • Vol up/down buttons change program number.
  • C619 burned.
  • No vertical deflection. on lower half screen.
  • Horizontal output transistor fails repeatedly.
  • Picture rolls. (25B8T06NXS tips)
  • Switches off by itself.
  • Brightness varies.
  • Top quarter of screen is lit. Rest of screen is black.
  • Upper part of picture is fuzzy and messed up, after was powered off for a few hours. (25B8T06NXS SANG repair tip)
  • No vertical deflection.
  • Slow start-up.
  • Red and green area on every side of the screen when warm. (25B8T06NXS SANG repair tip)
  • Low contrast.
  • Snow in picture.
  • No picture (intermittently). Audio OK .
  • Spots on the screen during shut off.
  • No AV.
  • Low tuner gain but can be tuned in.
  • Geometry adjustments.
  • Picture comes in after approx 1 min when started up from standby.
  • +B voltage is 20-80V instead 145V.
  • No picture. Red, green or blue raster.
  • Noise on some channels. (SANG - 25B8T06NXS information)
  • Squealing noise.
  • Horizontal line. Black screen. on lower half screen.
  • No functions.
  • Trips. after start-up. (25B8T06NXS SANG repair tip)
  • Switches to protection mode. after start-up.
  • Stripes in upper picture.
  • No focus.
  • Mains fuse is defective.
  • PSU pulsates. Standby LED flashes .
  • No power. (25B8T06NXS SANG repair tip)
  • B+ voltage (+140V) missing.
  • Enter service mode.
  • Volume increases to max.
  • PSU pulsates.
  • Vertical lines.
  • No synchronisation. No TXT.
  • Line output transistor fails repeatedly.
  • PSU blown after power failure.
  • No vertical deflection. Only a horizontal line at top.
  • Picture gradually disappears after start-up. Flyback lines, poor picture content.
  • Picture shifts. (SANG - 25B8T06NXS information)
  • Picture shifted to the left about 1 inch.
  • No picture. intermittently. OSD OK .
  • Dead. Standby LED does not light.
  • Stuck in standby.
  • Coloured spots on the corner.
  • Black dots on the screen.
  • Flyback lines. after warm-up.
  • No raster (intermittently). (25B8T06NXS tip from SANG)
  • Stuck in standby. Tripping noise at first switch-on. (25B8T06NXS tip from SANG)
  • No start-up.
  • Line tearing. intermittently. Squealing noise.
  • Distorted audio. via speakers.
  • Tripping.
  • AGC adjustment.
  • Brightness varies. intermittently. (25B8T06NXS tips)
  • Basic features. (25B8T06NXS tip from SANG)
  • R528, R530 and C524 defective.
  • C530 fails repeatedly. (25B8T06NXS SANG repair tip)
  • Excessive brightness. Flyback lines.
  • Reduced horizontal size. No E/W correction.
  • Vertical collapse.
  • No picture. intermittently. Audio OK .
  • Squealing from PSU (intermittently).
  • White picture with flyback lines from time to time.
  • Mains fuse blows sporadically.
  • Poor picture. after start-up.
  • No picture.
  • Trips.
  • No picture, only snow.
  • Switches to standby at start-up. LED flashes 2 times. (service info for SANG -25B8T06NXS)
  • Dead.
  • Changes picture size when increasing audio volume.
  • No 15V, 8V and 5V voltages.
  • Some channels missing.
  • Volume decreases to min.
  • Power supply blown. Mains fuse black. Possible lightning strike.
  • No 8V and 5V voltages. (service info for SANG -25B8T06NXS)
  • No start-up from standby.
  • Pulsating picture. Picture shrinks horizontally and expands vertically when changing brightness.
  • White lines.
  • HV builds up and then collapses.
  • Blurry picture.
  • Picture size varies with picture content.
  • Switches to standby. intermittently.
  • Stretched picture. intermittently.
  • No picture. on lower half screen.
  • No tuning.
  • Poor focus.
  • No picture. Audio OK .
  • How to test the PSU using a lamp.
  • Flyback lines.
  • No picture. intermittently.
  • Horizontal collapse. intermittently.
  • PSU pulses and there is popping from the speakers before set trips back to standby.
  • No start-up from standby. LED is red when switching.
  • PSU lamp test.
  • No RC functions.
  • Fuse (2.5A) is intermittently defective.
  • No TXT.
  • Switches channels automatically upwards. Maximum volume.
  • Cycles on/off. Knock sensitive. (service info for SANG -25B8T06NXS)
  • PSU collapses and trips as soon as appliance is swichted to full mode. Standby OK.
  • PSU does not start up correctly.
  • No HV.
  • No luminance.
  • No audio. No game. No calculator. (service info for SANG -25B8T06NXS)
  • Shuts down (intermittently). (25B8T06NXS tip from SANG)
  • No picture or sound via AV1. AV2 and AV3 ok.
  • Beeps now and again.
  • Flyback lines. intermittently. (25B8T06NXS tip from SANG)
  • No audio. (25B8T06NXS tips)
  • Protection mode activated. in standby.
  • Trips. at start-up.
  • Set trips at switch on.
  • Poor picture, exaggerated contrast and colours, brightness varies.
  • Poor picture.
  • Popping noise when switched off.
  • Tuning drifts. (25B8T06NXS tips)

When SANG 25B8T06NXS fails , these symptoms are known and EURAS knows the remedy/solution.

Tips are coming from EURAS customers, workshops and payed technicians from all over the world. SANG 25B8T06NXS fails can be better solved.

If SANG 25B8T06NXS fails, this information will help you. Here you can only see the symptom list, to access remedies, you must register.

With help of this list a solution is found often when SANG 25B8T06NXS fails.


Additionally to repairtips or service information 25B8T06NXS is linked to 59 components (IC's and/or transformers) in the Tectra database, through which you can identify electrical compatibilities (crossreferences) in appliances.


Chassis information is available (which chassis is built in into 25B8T06NXS ).

EURAS system also knows 745 appliances having the same chassis as 25B8T06NXS and can easily list them.

In the repair discussion pinboard for 25B8T06NXS there are 69 replies to questions asked about 81 different repair problems.
With access to EURAS you can all read them or enter your own questions and get help for 25B8T06NXS from EURAS technicians or other users.

Do want to see this remedies/cures for repairtips?   Register here for the EURAS System

Already registered? open 25B8T06NXS SANG in EURAS

All details on the EURAS System: English | Deutsch | Français | Italiano | Español | Magyarul | Português | Polski | Română | Greek |


Back to EURAS Homepage >> All manufacturers >> SANG tech tips  


(C) EURAS International Ltd.










Last updated: 30. Aug 2008 01:26:18 MET, doccode ISO9002AS168EKA200805C EURASMOP

Responsible for the content: EURAS International GmbH, Eime, Germany. All rights reserved, EURAS database V2.0 (C) 2002-2008. All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.