EURAS System
   EURAS worldwideeuras.com    
EURAS System

CEP2876N / SANYO [TV 67 (63) cm picture]

The EURAS repair tip database for professional technicians and service engineers supplies the following faults for CEP2876N / SANYO.

List of fault symptoms:
  • Q600 blown up.
  • Bright raster. Audio OK . (CEP2876N tip from SANYO)
  • No raster.
  • White screen. Flyback lines.
  • Unstable picture. Difficulty in tuning. OK with scart.
  • Reduced vertical size.
  • Snow in E-E.
  • Shuts down (intermittently).
  • Fast hiccup when connecting TV. LED flashes.
  • No picture, no sound, just snow when tuning selected.
  • No audio.
  • No function. No red LED.
  • Switches to standby. Squealing noise.
  • Unable to switch out of standby when cold.
  • No horizontal or vertical deflection.
  • No start up. Fast tripping.
  • Tuning drifts.
  • No vertical sync. In TXT only page no. visible.
  • PSU switching transistor fails at start-up.
  • Blank raster, sound OK. OK if used with Scart input from VCR. (SANYO - CEP2876N information)
  • Attempts to start up, but does not succeed and switches to standby.
  • How to call up SERVICE mode.
  • Transistor Q650 (BU508A) is S/C.
  • R653 continues to fail.
  • No picture, just snow when tuning selected. No sound
  • Red, green and blue flyback lines.
  • No HT or tube heaters.
  • Doesn't function even if standby LED lights up. When pressing mains switch, attempts to start up but goes to standby.
  • A few colour lines on top of picture.
  • White streaks.
  • No function. Standby LED OFF. Pressing Standby, cracking from PTC.
  • Vertical collapse.
  • Slow response to channel change, takes 20-30 secs to change. (SANYO - CEP2876N information)
  • Very dark and greyish picture.
  • No picture. Audio OK .
  • No picture. No sound. Rattles.
  • Clock flashing O S G text clock OK. (CEP2876N SANYO repair tip)
  • E/W fault. intermittently.
  • Dead.
  • No E/W correction.
  • No start up after being turned off for several hours. It eventually starts up when attempting to switch on several times.
  • Mains fuse blown.
  • Flyback lines. at top.
  • No picture.
  • Enter service mode.
  • Collapses to a thin bowed horizontal line.
  • E/W fault.
  • SERVICE mode:
  • Corrupted data.
  • Pincushion distortion. 5cm field collapse on each screen edges.
  • Vertical folover at bottom and insufficient height. Approx 20cm stripe on centre of screen.
  • Lines in picture. at top.
  • Excessive horizontal size. Pincushion distortion.
  • Starts up, functions for a minute and immediately disconnects, remaining in standby.
  • Switching FET (BUZ90A) defective.
  • No luminance signal. In TXT only page no. is visible.
  • No vertical deflection.
  • Excessive brightness. Audio OK .
  • Stuck in standby.

If SANYO CEP2876N fails, this information will help you. Here you can only see the symptom list, to access remedies, you must register.

With help of this list a solution is found often when SANYO CEP2876N fails.


Additionally to repairtips or service information CEP2876N is linked to 26 components (IC's and/or transformers) in the Tectra database, through which you can identify electrical compatibilities (crossreferences) in appliances.


Chassis information is available (which chassis is built in into CEP2876N ).

EURAS system also knows 23 appliances having the same chassis as CEP2876N and can easily list them.

In the repair discussion pinboard for CEP2876N there are 5 replies to questions asked about 7 different repair problems.
With access to EURAS you can all read them or enter your own questions and get help for CEP2876N from EURAS technicians or other users.

Do you want to see this remedies/cures for repairtips?   Register here for the EURAS System
Please note: access to the EURAS System can be granted only to professional household electronics repair shops/technicians/Video/TV which are authorized for service by a manufacturer, or can prove to be professionally certified to do repairs on electronic appliances. You will be asked for a statement and information accordingly during registration.

If you do not qualify as stated above and you have an appliance that needs technical service, we do recommend you to contact the manufacturer (for example through his website) or go to a professional household/TV/Video electronics repair shop close to you.

Already registered? open CEP2876N SANYO in EURAS

All details on the EURAS System: English | Deutsch | Français | Italiano | Español | Magyarul | Português | Polski | Română | Greek |


Back to EURAS Homepage >> All manufacturers >> SANYO tech tips  












Last updated: 01. Dec 2008 23:31:30 MET, doccode ISO9002AS168EKA200805C EURASMOP

Responsible for the content: EURAS International GmbH, Eime, Germany.
All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.