List of fault symptoms:
- Switches to standby. after start-up.
- Stuck in standby. Red LED flashes for a short while.
- Switches to standby. intermittently.
- Stuck in standby. LED is green then red.
- Black screen.
- R809 (0R47) defective and Q801 (P3NA60) s/c.
- PSU drops out.
- No vertical deflection.
- No horizontal synchronisation (intermittently). Switches to standby.
- No start-up. Red LED lit and blinks when button CH (+) or RC is pressed. No green LED.
- Clicking noise.
- No HV. Audio OK .
- No functions. LED is red .
- Shuts down for a sec. Standby LED also switches down for a sec.
- Total failure, PSU pumps.
- Poor picture. Intermittent colour. Flashing picture.
- Shuts down. LED is red .
- No display.
- Dead. Standby LED does not light.
- Line output transistor fails repeatedly. after a while.
- Standby LED is red and TV trips. LED flickers when trying to start up.
- Dead.
- Picture height only approx. 15cm and compressed at the bottom.
- Horizontal line and approx 5 cm picture content. (CT5500 TECHLINE repair tip)
- PSU ticking. Red LED blinks.
- No HV.
- Dead. LED is red . (TECHLINE - CT5500 information)
- Can be switched on via RC or PR +- on appliance only after several attempts.
- Line tearing.
- Horizontal lines have notches (mouse teeth).
- Picture is red, bright parts have a bluish tint.
- Stuck in standby. Red LED turns green for a sec when trying to turn on.
- Standby is lit, cannot be switched on. Smells burnt.
- Flashing picture.
- Switches to standby. at start-up.
- Line output transistor fails repeatedly.
- No picture. via SCART. Audio OK .
- Goes to standby immediately after switch on.
- Bright raster. Flyback lines.
- No front panel function.
- Line BU fails after approx.10-20 min.
- Changes the channel after approx. 10 min. on the program site. Switches off when calling up the menu, returns with OSD shifted to the left.
- No TXT. No switch-over, page number is displayed but no picture content.
- Standby only, does not switch on via RC or control unit. Red LED flashes.
- No picture. after a few minutes.
- Clicking noise. in standby.
- No sound. Installation menu cannot be called up.
- Tripping. Red LED blinks.
- Line output stage BU808DFI is defective.
- Trips.
- PSU fails. (TECHLINE - CT5500 information)
- Picture slightly wider than normal. No vertical amplitude. Picture and sound intermittent drop out.
- Noise on sound via HF. OK via AV. (service info for TECHLINE -CT5500)
- Picture shifted vertically.
- No functions. at start-up. LED blinks .
- Switches to protection mode. (CT5500 tips)
- Variation of PSU voltages.
- No E/W correction.
- No start-up. Red LED blinks.
- No OSD. Picture foldover. Bad linearity.
- No or poor picture. (TECHLINE - CT5500 information)
- No start-up. LED lit. .
- Does not shut down. No colour.
- Blue disc capacitor C812 blown.
- Only a horizontal line or no picture.
- No start-up. LED is red .
- Control keys do not function. (CT5500 tip from TECHLINE)
- LED is green after start up, squeaking.
- LED remains red with a slight flickering at start-up. If it starts up, PSU transformer whistles.
- No function, LED faintly flashes green, smells burnt.
- Shuts down. after start-up.
- Starts up briefly. LED is alight.
- Tube overfeeds. Flyback lines.
- No horizontal deflection.
- No picture. LED is green.
- E/W fault.
- No HV after diode D805.
- PSU pulsates. LED is green. Tripping. after start-up.
- Difficoult startup when cold, LED flashes and goes back to standby.
- Stuck in standby. Tripping.
- Slow start-up.
- No audio. Crackling audio. via speakers. (CT5500 tip from TECHLINE)
- Dead. Green LED flashes .
- No start-up. LED blinks .
- Keine Funktion, Standby OK. Nach Einschalten LED kurz grün, dann wieder rot.
- No functions. LED blinks .
- Ticking noise. in standby.
- Line output transistor Q603 (BU808) breaks down after 1hour runtime.
- No picture. OK via SCART .
- PSU pulsates. Red LED blinks.
- How to enable PAL standard for UK use.
- Goes to standby automatically every 5 min.
- No picture. Green LED flickers when trying to start up.
- Floating moire-effect distortion around CRT.
- Low audio.
- No start-up. LED is green.
- Geometry adjustment.
- Slightly distorted picture. Slowly runs from the top to the bottom or gets stuck. Sound is slightly distorted.
- Vertical foldover. after warm-up.
- Horizontal lines.
- PSU pulsates.
- Stuck in standby. LED is red .
- Standby LED starts to flash after switch on.
- Enter service mode.
- No start-up from standby.
- Dead. Standby LED flashes .
- No function, standby OK. LED lights green for a short time, then becomes red again.
- No audio. via AV.
- No line drive pulses. (service info for TECHLINE -CT5500)
- Reduced vertical size. (service info for TECHLINE -CT5500)
- Excessive vertical size.
- Loud noise. in standby.
- No HV. Green LED flashes .
- Green LED is lit at switch on via RC, otherwise no function.
- PSU trips, pumps after switch on.
- Ripple on screen.
- BU808 fails after an hour.
- No channels.
- Ticking noise.
- No picture. Audio OK .
- Vertical collapse.
- Shuts down after start-up. HT heard.
- PSU Blown.
- At switch on blank raster, timer counts back from 5 min and set switches off.
- LED flashes green/red after switch on.
- La LED verte est allumée lors de l'allumage avec la TC. Autrement pas de fonctions.
- Noise in standby.
- No start-up.
- Dark picture (intermittently).
- Distorted and wavy picture. No AV input. AV output ok.
- No PSU or pumps. (CT5500 TECHLINE repair tip)
- PSU pulsates. LED is dark. (TECHLINE - CT5500 information)
- No start-up. LED becomes green briefly, then reverts to red. (CT5500 tips)
- No start-up from standby. Red LED blinks.
- Disable hotel mode.
- Line output transistor fails repeatedly. after a few minutes.
- Excessive horizontal size. Pincushion distortion.
- No picture. (service info for TECHLINE -CT5500)
- No sound, no picture. Appliance is pumping regularly and green LED flashes briefly.
- Stuck in security.
- Q603 (BU808DFI) overheats.
- Excessive brightness.
- White horizontal line in the middle of the picture.
- Dead. LED lights dimly.
- Vertical fault. Picture is only 5cm high (from the middle of the picture to the bottom).
- Vertical foldover at top.
- No raster.
- No function. PSU works without a fault in protection mode.
- Grüne LED leuchtet beim Einschalten mit FB, sonst keine Funktion.
- PSU does not start up. LED flashes red/green.
- Tripping. LED blinks .
- Venetian blind effect.
- Excessive horizontal size.
- Switches to standby. after a few seconds.
- When stopping TV via RC, diode stays green and doesn't get red. Picture and sound are OK in standby but line transformer makes a fluttering noise. When restarting via RC, picture, sound and functions are OK.
- No functions.
- Tripping.
- Reduced horizontal size.
- No picture. Noise in picture. No tuning.
- PSU pulsates. at start-up.
- Slow start-up. when cold. (service info for TECHLINE -CT5500)
With help of this list a solution is found often when TECHLINE CT5500 fails.
|
Additionally to repairtips or service information CT5500 is linked to 186 components (IC's and/or transformers) in the Tectra
database, through which you can identify electrical compatibilities (crossreferences) in
appliances.
|
Chassis information is available (which chassis is built in into CT5500 ).
EURAS system also knows 544 appliances having the same chassis as CT5500 and can easily list them.
In the repair discussion pinboard for CT5500 there are 90 replies to questions asked about 76 different repair problems. With access to EURAS you can all read them or enter your own questions and get help for CT5500 from EURAS technicians or other users.
Do you want to see this remedies/cures for repairtips? Register here for the EURAS System Please note: access to the EURAS System can be granted only to professional
household electronics repair shops/Video/technicians/TV which are
authorized for service by a manufacturer, or can prove to be professionally
certified to do repairs on electronic appliances. You will be asked for a
statement and information accordingly during registration.
If you do not qualify as stated above and you have an appliance that needs
technical service, we do recommend you to contact the manufacturer (for
example through his website) or go to a professional household/TV/Video
electronics repair shop close to you.
Already registered? open CT5500 TECHLINE in EURAS
All details on the EURAS System: English |
Deutsch |
Français |
Italiano |
Español |
Magyarul |
Português |
Polski |
Română |
Greek |
Back to EURAS Homepage >>
All manufacturers >>
TECHLINE
tech tips
Last updated: 07. Oct 2008 18:16:10 MET, doccode ISO9002AS168EKA200805C EURASMOP
Responsible for the content: EURAS International GmbH, Eime, Germany.
All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.
|
|