List of fault symptoms:
- No picture or intermittent picture when hot.
- No manual or remote channel change, mute light on.
- No audio.
- No power supply output.
- Pincushion distortion with brightness fault.
- Destruction of chopper transistor TR62.
- Intermittent graphics on display.
- Ballooning effect.
- No or weak signal.
- No sync, RCU function or sound.
- AGC overload CH2 only.
- Intermittent colour.
- One colour is missing or excessive.
- After 30 mins, set goes into standby. Relay chattering.
- Volume fault.
- No standby via RC. LED OK.
- Synchronisation faults.
- No RCU and no functions without remote lead removed.
- Set intermittently fails to start up or goes off at random.
- Interference from fluorescent light.
- Focus problems.
- Trips. Hum from speaker.
- Terrible field linearity.
- IC601 (TDA3560) becomes defective after a short time.
- General frame or field defects.
- Vertical foldover.
- Tuning comes back after being off tune for first 5-10 minutes at switch on. (6093 ULTRA repair tip)
- Ripple on picture with reduced width. Clears after a while.
- No functions, power supply is working.
- Uncontrollable sound high.
- Over volts surge at switch on.
- Offset picture to the right. (with circuit diagram extract)
- Intermittent RCU functions.
- No standby if switched off/on from mains socket.
- Tuning drift. Does not tune low frequency channels. (6093 tip from ULTRA)
- Flyback lines.
- Ringing on verticals.
- Vertical collapse.
- No sync. Sound muted.
- Frame fold over at top of screen with bright line across middle of screen.
- Mute LED on. (6093 tips)
- Picture narrowing from the sides.
- No sound (R156 burnt out is open circuit).
- Sound is excessive and cannot be controlled. Remote volume changes the brightness.
- When replacing frame output IC. (TDA3652 is no longer available.
- Weak contrast.
- Intermittent HT (135V). (6093 ULTRA repair tip)
- After heating up, the timer lock is very weak. If you change channels, the line synchronisation is occasionally correct but it goes wrong in relation to the frame synchronisation.
- Noise bars.
- Intermittent low gain.
- Stuck in standby. Receiver ticking.
- Low audio.
- No picture or sound. LEDs lit.
- No operation (intermittently).
- Field foldover at top with reduced width.
- No RC. Stuck on channel.
- Picture is grainy and sound noisy.
- Picture unstable with patterning.
- No RC functions. Manual OK if RC lead disconnected.
- Radio and TV are dead.
- After approximately 20 minutes line tearing occurs.
- RC control effected by fluorescent light.
- Relay chatters.
- Line twitching.
- Insufficient height and width.
- Unsteady frame scan, lines may be present.
- Line tearing after 20 mins.
- Low gain.
- Black fuse. (6093 tips)
- Goes into standby every 10 mins.
- Picture flutters at certain brightness and control levels.
- Intermittent cuts out of all voltages except 12V.
- No scan.
- Line drift.
- Line frequency drifting.
- Very faint sound. (6093 ULTRA repair tip)
- Standby LED stays on.
- Poor sync when warm.
- Insufficient purity.
- No RCU function, no front control function.
- Colour is missing on teletext.
- Sound blasts out. Colour and brightness varies.
- Intermittent crackle on left hand channel and plop when sound is muted. (6093 tips)
- Sound blares/brightness and colour varies.
- Clock and radio only, no TV.
- Flyback lines at top 1in.
- Line twitch.
- Blowing field output IC.
- Goes into standby or LED reads incorrect.
- Various hum bars or distorted picture.
- Interruptions.
- Battery dead.
- Appliance is slow to come on, about 10 seconds.
- Line synchronisation is weak and does not lock when cold.
- Snow or ghosting.
- Only lower half of text correct.
- PSU only starts intermittently. Sometimes it starts once a day but not in successive occasions.
- Blurry picture.
- Intermittently when the appliance is warm the RCU does not function.
- Trips.
- Grainy picture.
- Sound OK but no line.
- Small frame.
- Picture interference plus noise on sound.
- Appliance remains on programme 8.
- No switching to standby with RC (LED lit).
- Teletext drop out on one or two channels.
- No line sync.
- Height drifts.
- Field collapse, no sound and reduced width.
- Dark picture. No sound. Stuck in mute. No RC functions.
- Lines flash on picture, may not affect all channels.
- Wrong channel display.
- Low brightness.
- Width is reduced and East-West correction is poor.
- Excessive EHT damaged IC55 (TDA1170S).
- No picture and severe hum.
- Incorrect line speed. AV channels OK on prerecorded tapes.
- When appliance is warm synchronisation is weak.
- The appliance does not turn on from standby and then sticks on channel 1. (ULTRA - 6093 information)
- Lines flash on picture, may only affect some channels.
- EHT is excessive, IC55 (TDEA1170S) is damaged.
- Rolling with dark scenes. (6093 tip from ULTRA)
- F51 blown intermittently.
- When appliance is switched on the mains fuse blows.
- Loss of picture after 10 mins.
- Dead. High pitch whistle.
- Gain is low.
- Dead. Channel indicator OK.
- Noise bars across picture.
- Low gain.
- No or weak colour.
- Volume varies.
- Cracks, crackling or sizzling, possibly with fine white lines. (service info for ULTRA -6093)
- Hum from set.
- Squealing noise from chopper Tx.
- Shuts down after a few mins.
- No picture or picture flashing.
- Frame collapses, total collapse at bottom and half scan at top,can be intermittent. (6093 ULTRA repair tip)
- Stereo LED permanently on.
- Picture is missing, raster and sound correct.
- Line frequency appears on part of screen, when cold.
- No standby from remote (LED lights).
- No remote stuck on channel 8/6.
- The sound is ok, no conductor.
- E/W fault.
- RC works when a few feet away only.
- Thin lines across screen.
- Does not change channels.
- No remote functions step up/down button only.
- Colour fault.
- Will not come on if switched back on while still warm.
- Field roll (off air).
- Line lock is lost on all but video channel.
- Line pulling during warm up.
- Line collapses intermittently.
- The appliance blows line output transistor at switch on. (6093 tip from ULTRA)
- Field jitter with black lines across picture.
- Black lines at top of screen, increasing when warm.
- Line sync drift on TXT only.
- Intermittently goes into standby or TXT.
- No picture. No audio. Raster OK .
- No manual channel change. OK on RCU.
- Incorrect LED eg. 11 for 1 or 22 for 2.
- Line hold out of phase lock.
- Mains voltage hum: defective scanning, dirty. Birgit??
Lynn, I don't really know what is dirty. Could it be the degauss coil?
- Shading in picture.
- Blank screen with no RCU functions.
- HT and LT low.
- Line faults.
- Intermittent start up then tripping with ticking. (ULTRA - 6093 information)
- No red or red band at top of picture.
- Dead. Slight ticking noise.
- No RCU. No tuning.
- Intermittent line collapse then fades off.
- Dark picture.
- Appliance is dead, just low ticking.
- Reduced vertical and horizontal size.
- Vertical fault.
- Intermittent loss of sound and raster.
- No start-up. after warm-up.
- Poor picture, lack of contrast.
- Picture and sound are missing, raster ok.
- In standby when switched on or audio at maximum.
- No picture when cold.
- Buzz on sound but only in the standby position. (6093 tip from ULTRA)
- No function.
- Enter service mode.
- Teletext message stays on and/or channels change at random.
- Picture is missing, sound ok.
- Intermittent black fuse.
- When replacing frame output IC, TDA 3652, no longer available. (6093 tip from ULTRA)
- No picture or sound. Channel indicators OK.
- Picture is very noisy.
- Picture blacks out to white raster.
- No RC functions.
- IC101 (SAA5012) repeatedly fails on PC1515.
- Height problems.
- HT supply is high.
- Blank screen in TXT mode and only black graphics in mix mode.
- Smearing in picture.
- 115V HT rail reads high.
- Appliance switches off and back on. Fault diminuates after a few hours.
- Field linearity problems. (6093 tips)
- Goes to standby when channel change selected intermittently.
- Excessive readings on all HT supplies from chopper transformer.
- No picture. Sound OK.
- When sound mute LED is on, no channel display/RCU functions.
- Solenoid operates approx about 1 min.
- IC57 and TR62 blown.
- Vertical jitter.
- Intermittent poor grey scale then video goes off.
- Distorted field scan.
- Frame foldover or creeping. (6093 ULTRA repair tip)
- Brightness pulsating.
- One colour poor, others ok.
- No TXT (intermittently). (6093 tip from ULTRA)
- Intermittent field sync.
- Width defects.
- No TXT. Page number only.
- Line pairing at top & bottom of screen.
- Poor picture focus. (service info for ULTRA -6093)
- Screeching noise from LOPT and D28 (BY299) S/C.
- No remote function after 30 minutes.
- Appliance is slow to start up and the picture pulses.
- Tuning fault (channel 1 memory has disappeared).
- Sound mute LED on. No channel display or RC function.
- At switch on line synchronisation is missing. (picture attached)
- Brightness fault.
- Black lines across top 1/3 spreading as set warms.
- Intermittent picture and sound; similar to tuner fault.
- Low HT when warm.
- Distorted sound right channel (mono or SS).
- Teletext black box stays on screen.
- Contrast control does not function correctly.
- No sound or picture, channel indicator lit, high tension is normal value.
- The appliance has a dark picture.
- Goes into standby or intermittently changes channel.
- Non-linear field scan.
- After a few hours the line collapses.
- 115V rail high (137V) bent verticals/ whistle.
- Lines flashing on picture, may not affect all channels.
- Beam sensing fault.
- Picture disturbance with change of picture content.
- No audio (intermittently).
- RCU does not control volume, contrast, colour or brightness.
- Intermittently dead. When OK intermittent sound mute and channel change.
- Intermittently dead. Slight tripping and video fault.
- No picture. Intermittent LED display.
- Reduction of field scan to 2-3 inches.
- Remote control does not work from standby, stays on channel one.
- Line appears to break-up with bright blue picture.
- Frame bounce when cold.
- No picture, no Eht no heaters all Ht's slightly low.
- Tuning drifts. (6093 tip from ULTRA)
- No sound and mute light glowing slightly.
- No sound or raster (low frequency popping noise).
- Destroys TR8.
- No line drive.
- No RC functions except for step up and down buttons.
- No picture. Radio sound on all channels.
- Voltages from chopper transformer are too high.
- Incorrect line speed. Intermittently OK when switched to AV channel and back again.
- Reduced horizontal size.
- Line linearity problems.
- CRT problems.
- Appliance does not function. Mains fuse blows.
- Line frequency incorrect.
- Will not start.
- No picture just lines.
- No output from IC1807.
- Blows fuse. Line output transformer is noisy then fuse blows again.
- Intermittent on/standby. Remains on Ch8 with mute LED on.
- Horizontal black lines on screen.
- Low contrast.
- LED shows 88.
- Intermittently dead then permanently dead.
- Set won't start up. (ULTRA - 6093 information)
- Low h.t.
- No picture blank out on teletext.
- Standby light flashing when switched on, then appliance goes dead.
- Blank raster, standby LED on display shows 8, 88 or 888.
- No field sync. Picture rolls.
- Faulty line sync.
- No colour.
- No sound, no channel change.
- Dead.
- Picture pulsating and changing colours.
- Low line frequency.
- No sync on TXT.
- 1.6A mains fuse blowing.
- Lines flash on picture, may be affect all channels.
- No vision or sound. Incorrect LED display, no RCU functions.
- Difficult line lock from cold. Line pulls.
- Black lines at top 1/3 increasing as set warms up.
- No RCU functions.
- No colour.
- Incorrect picture size.
- Distorted audio.
- Striations down left hand side. (6093 ULTRA repair tip)
- Line drifts off frequency.
- Tuning drifts, patterning.
- Blowing mains fuse start up IC57 and chopper transistor TR62.
- No audio.
- No line sync at switch on.
- No width or pin cushion control. (ULTRA - 6093 information)
- Very intermittent failure to start up (works normally for days or even weeks).
- Buzz in audio.
- Blows fuse. Screeching noise from LOPT prior to blowing fuse.
- Low numbered channels cannot be stored.
- Will not come out of standby. (PC1044)
- Very weak vision with little or no sync.
- Blows TR66 and mains fuse intermittently.
- Appliance hums (mechanically). (6093 tips)
- No frame sync.
- Cramped frame.
- Contrast problems.
- No picture, no sound. Standby LED on.
- Contrast control not working.
- Flyback lines at bottom of screen, increasing in size over bottom third. Lines are always green.
- Line output transistor TR68 blown.
- Stiations. (ULTRA - 6093 information)
- Sound on vision effect.
- Width control gives only maximum or minimum width.
- No channel indication. No tuning.
- No manual functions. RCU functions OK.
- No line/field sync, no sound (muted) and no TXT.
- Colour on teletext is missing.
- Line collapse after a few hours.
- TR66 and mains fuse blown intermittently.
- Failure of TR10.
- Defective line linearity.
- Contrast control O/C.
- Small picture and screeching, blows VT68.
- When pressing buttons 1 to 5 the channels activated are 5 to 8.
- At switch on crowbar fires and blows fuse.
- The appliance goes into standby intermittent if channel change is selected.
- Tuning fault (IC901 loses the memory after 1 week). (6093 tips)
- High pitched whistle from left hand loud speaker.
- Focus out.
- IC101 (SAA5012) repeatedly faulty.
- (Pg 1 of 2) Dead.
- Contrast control not fully operative.
- All HTs high from chopper transformer.
- Vertical roll.
- No functions. Very dark.
- Drop out on TXT.
- Field collapse. No sound, no LEDs lit.
- Field collapse. No sound or brightness.
- Line tearing varies with level of brightness and contrast.
- Will not tune below CH28 and drifts slightly with no affect.
- No functions.
- Reduced vertical size.
- Does not switch to standby.
- Intermittent fault ,no manual or remote channel change and only the mute light on.
- Intermittently 119V rail varies.
- Intermittently destroys TR8.
- Picture shifted to left hand side by about 1/3.
- No AV CH8.
- Starts in standby and squeals.
- Relay clicking over. No LED or EHT. (service info for ULTRA -6093)
- Picture breaks up with change of picture content.
- No fastext functions.
- Blows TR10 at switch-on.
- No picture at switch on.
- Teletext problems.
- Picture disappears intermittently.
- Intermittently blows chopper transistors.
- Contrast control is open circuit (burnt).
- Humming on standby. Radio scale light remains on.
- Comes on in standby.
- Very bad line pairing top and bottom.
- Picture offset to the right hand side. (6093 tips)
- Intermittent strat-up, then trips with ticking noise.
- Set will not come out of standby. (6093 tip from ULTRA)
- Intermittent remote control function eg. no colour excessive.
- No E-W correction. (6093 tip from ULTRA)
- Bright picture with flyback lines.
- Green flyback lines at bottom of screen.
- Occasionally appliance does not function.
- No RC functions (intermittently).
- Stuck on programme 8. (6093 tips)
- No vertical deflection.
- Poor function. (6093 tip from ULTRA)
- Field hold critical. (6093 tips)
- Blows mains fuse.
- Corrupted TXT. Displaced to left hand side.
- Zig Zag verticals.
- Trapezoid picture.
- Insufficient blue.
- Humming.
- Black smearing on peak whites.
- Goes to standby a few times.
- Speaker problems.
- Colour is missing or not correct.
- Green looking faces.
- No channel storing. (service info for ULTRA -6093)
- No standby picture control.
- Blows line output transistors at switch-on.
- Grey scale fault (TDA3560) CRT trouble.
- Intermittently dead.
- 115V rail takes anything up to 5 mins. to occur.
- No mute, standby or volume +/-. Channel change OK.
- Poor or no RCU operation at close range.
- No AV on channel 8 and 9. OK AV on channel 1-7.
- Occasionally RCU function has no colour or too much colour. (6093 tip from ULTRA)
- Field cramping.
- Width problems. (6093 tip from ULTRA)
- Hanover bars and incorrect colour.
- Blank raster, no sound preceded by arcing.
- Only min or max width control.
- RCU does not function, remains on channel.
- Green flyback lines at the bottom of screen.
- No function of RC during standby. Stays on channel 1.
- Field linearity is poor.
- Dead. LEDs lit.
- Sound on vision.
- Line collapse intermittently.
- No TXT.
- Screeching noise from PSU. Ripple effect on screen.
- Picture shifted to the left. (service info for ULTRA -6093)
- Appliance is dead, HT voltage at approximately half. Channel indicator ok.
- No LED display.
- Line lock lost at switch on and when changing channels. No signals.
- TDA1170S field chip is U/S.
- Picture flutters when various brightness and contrast levels selected. (service info for ULTRA -6093)
- No RCU functions. Manual functions OK.
- Amplification is too weak.
- Appliance does not function; 115V is too low and fuse FS1 blows after a short time. (6093 ULTRA repair tip)
- Field jitter. Intermittent colour. No TXT.
- Set will not start.
- Excessively bright raster.
- Field foldover at top half of scan.
- Appliance and LED fades at switch on.
- Intermittently goes into standby, volume variations and scrambled teletext.
- No synchronisation.
- Slow to come on.
- Intermittent channel change. After channel change red LED is lit for a while.
- Line output and driver transistors blown up.
- No audio. LED is green.
- Picture is small.
- Fuse blowing L65 hot 115V high.
- During monochrome transmissions, colour breaks through.
- Ghosting effect.
- Pincushion distortion.
- Colour fault on teletext.
- Blowing BU508 at switch-on. (ULTRA - 6093 information)
- Frame rolling.
- Radio and TV do not work.
- Smearing on peak whites.
- Stuck in standby.
- Intermittent roll when hot.
- Poor field sync with computers.
- Arcing then blank raster.
- Pattern on TXT.
- Striation effect.
- Comes up slowly with picture pulsating. (6093 ULTRA repair tip)
- Appliance intermittently pulses off then on again, after running it for several hours the fault becomes more frequent.
- RCU transmitter problems.
- No picture, no sound. Low frequency popping noise.
- Reduced picture with screeching noise.
- Blank raster, sound OK.
- Teletext message stays on screen.
- No TV or radio. Clock OK.
- No picture.
- Bent verticals.
- No TXT on some channels.
- Stations can be searched for and found but not memorised.
- Changes channels at random and goes into standby. (service info for ULTRA -6093)
- Vertical collapse (intermittently).
- No tuning.
- Patterning on all channels.
- Picture shifted to right with a black band down left hand side.
- Stuck in standby via RC. Locked on CH1.
- Red looks fluorescent, other colours appear weak.
- Moire pattern.
- Line synchronisation is missing.
- Picture is missing, just a green raster with flyback lines.
- Ticking noise in standby. (6093 tip from ULTRA)
- Poor sync lock when warm (approx 10 mins after switch on). If channel changed, line sync sometimes pulls in ok but at other times, slips through with field sync.
- Blank raster.
- Negative picture.
- No RC functions after 30 mins.
- Picture blanked out on TXT. (6093 tip from ULTRA)
- Poor line sync.
- Snow in picture. No channel display.
- The line control transistor T9062V TR67 has a short circuit and mutilates the safety resistor R222 (collector circuit).
- Bent verticals and whistle.
- Poor field sync with computers.
- Picture collapses.
- Solenoid operates after about 1 minute.
- Tuning fault (audio mute and channel change with the previous/following key fails).
- No TXT. Picture remains and is displaced to left.
- Displays AGC off tune errors for first 30 mins after switch on.
- Low contrast/weak picture and weak field sync. Colour OK.
- No field sync and no sound.
- Black horizontal lines across the screen.
Tips are coming from EURAS customers, workshops and payed technicians from all over the world. ULTRA 6093 fails can be better solved. If ULTRA 6093 fails, this information will help you. Here you can only see the symptom list, to access remedies, you must register. With help of this list a solution is found often when ULTRA 6093 fails.
|
Additionally to repairtips or service information 6093 is linked to 3 components (IC's and/or transformers) in the Tectra
database, through which you can identify electrical compatibilities (crossreferences) in
appliances.
|
Chassis information is available (which chassis is built in into 6093 ).
EURAS system also knows 85 appliances having the same chassis as 6093 and can easily list them.
In the repair discussion pinboard for 6093 there are 17 replies to questions asked about 4 different repair problems. With access to EURAS you can all read them or enter your own questions and get help for 6093 from EURAS technicians or other users.
Do want to see this remedies/cures for repairtips? Register here for the EURAS System
Already registered? open 6093 ULTRA in EURAS
All details on the EURAS System: English |
Deutsch |
Français |
Italiano |
Español |
Magyarul |
Português |
Polski |
Română |
Greek |
Back to EURAS Homepage >>
All manufacturers >>
ULTRA
tech tips
(C) EURAS International Ltd.
Last updated: 22. Aug 2008 12:11:07 MET, doccode ISO9002AS168EKA200805C [cachelite] EURASMOP
Responsible for the content: EURAS International GmbH, Eime, Germany.
All rights reserved, EURAS database V2.0 (C) 2002-2008.
All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.
|
|