List of fault symptoms:
- No HV. Green LED flashes .
- No function, LED faintly flashes green, smells burnt.
- No HV after diode D805.
- No picture. Audio OK .
- No sound. Installation menu cannot be called up.
- No start-up.
- Ripple on screen.
- Picture is red, bright parts have a bluish tint.
- Clicking noise.
- No sound, no picture. Appliance is pumping regularly and green LED flashes briefly.
- Excessive vertical size.
- Variation of PSU voltages.
- Tube overfeeds. Flyback lines.
- No start-up. LED blinks . (WD5516RF tip from WINDSOR)
- No horizontal synchronisation (intermittently). Switches to standby.
- Dead.
- Standby LED is red and TV trips. LED flickers when trying to start up.
- Dark picture (intermittently).
- Difficoult startup when cold, LED flashes and goes back to standby.
- No OSD. Picture foldover. Bad linearity.
- Only a horizontal line or no picture.
- Horizontal lines.
- Switches to standby. after a few seconds.
- Switches to standby. at start-up.
- Dead. LED is red .
- Line output stage BU808DFI is defective.
- No picture. Noise in picture. No tuning. (WD5516RF tips)
- PSU pulsates. at start-up.
- No TXT. No switch-over, page number is displayed but no picture content.
- No start-up. LED is green. (service info for WINDSOR -WD5516RF)
- Stuck in standby. Red LED turns green for a sec when trying to turn on.
- PSU trips, pumps after switch on.
- No picture. via SCART. Audio OK .
- Tripping. LED blinks .
- Shuts down. after start-up.
- White horizontal line in the middle of the picture.
- No start-up from standby.
- Switches to standby. intermittently.
- No start-up. Red LED lit and blinks when button CH (+) or RC is pressed. No green LED.
- Slightly distorted picture. Slowly runs from the top to the bottom or gets stuck. Sound is slightly distorted.
- No start-up from standby. Red LED blinks.
- No picture. OK via SCART .
- Flashing picture.
- Switches to standby. after start-up.
- Line output transistor fails repeatedly. after a while.
- Dead. LED lights dimly.
- LED is green after start up, squeaking.
- PSU fails.
- Poor picture. Intermittent colour. Flashing picture.
- No picture. Green LED flickers when trying to start up.
- No start-up. LED lit. . (WD5516RF WINDSOR repair tip)
- Dead. Green LED flashes .
- LED flashes green/red after switch on.
- Vertical foldover. after warm-up.
- No audio. via AV.
- No line drive pulses.
- Vertical foldover at top.
- No picture. after a few minutes.
- No horizontal deflection. (WD5516RF tip from WINDSOR)
- Enter service mode.
- Reduced vertical size. (WD5516RF tips)
- At switch on blank raster, timer counts back from 5 min and set switches off.
- Total failure, PSU pumps.
- Venetian blind effect. (WD5516RF tips)
- Horizontal lines have notches (mouse teeth).
- PSU Blown.
- PSU ticking. Red LED blinks.
- Tripping.
- Trips.
- BU808 fails after an hour. (service info for WINDSOR -WD5516RF)
- PSU does not start up. LED flashes red/green.
- Switches to protection mode.
- No raster.
- Shuts down for a sec. Standby LED also switches down for a sec.
- Standby is lit, cannot be switched on. Smells burnt.
- No function. PSU works without a fault in protection mode.
- Starts up briefly. LED is alight.
- Ticking noise.
- PSU pulsates.
- LED remains red with a slight flickering at start-up. If it starts up, PSU transformer whistles.
- Line BU fails after approx.10-20 min.
- No E/W correction.
- Stuck in standby. LED is green then red.
- Control keys do not function.
- Horizontal line and approx 5 cm picture content.
- Goes to standby immediately after switch on.
- R809 (0R47) defective and Q801 (P3NA60) s/c.
- Noise on sound via HF. OK via AV.
- Noise in standby.
- Clicking noise. in standby.
- Green LED is lit at switch on via RC, otherwise no function.
- Shuts down after start-up. HT heard.
- Dead. Standby LED flashes .
- Picture slightly wider than normal. No vertical amplitude. Picture and sound intermittent drop out.
- Standby LED starts to flash after switch on.
- Floating moire-effect distortion around CRT.
- Line output transistor Q603 (BU808) breaks down after 1hour runtime.
- Distorted and wavy picture. No AV input. AV output ok.
- E/W fault.
- PSU pulsates. LED is green. Tripping. after start-up. (WINDSOR - WD5516RF information)
- No PSU or pumps.
- Picture shifted vertically.
- No picture. LED is green.
- Ticking noise. in standby.
- No function, standby OK. LED lights green for a short time, then becomes red again.
- No HV. (WD5516RF tips)
- No functions. LED blinks .
- No functions. LED is red .
- No vertical deflection.
- Dead. Standby LED does not light. (WINDSOR - WD5516RF information)
- Stuck in standby. Tripping.
- No HV. Audio OK .
- No display.
- How to enable PAL standard for UK use.
- Standby only, does not switch on via RC or control unit. Red LED flashes. (WINDSOR - WD5516RF information)
- No picture.
- Starts up immediately in protective switching. (Pumps.)
- No start-up. LED is red .
- Slow start-up.
- No front panel function.
- Stuck in security.
- No functions. at start-up. LED blinks . (WD5516RF WINDSOR repair tip)
- PSU pulsates. LED is dark.
- No or poor picture.
- Stuck in standby. LED is red .
- Bright raster. Flyback lines.
- No audio. Crackling audio. via speakers.
- Blue disc capacitor C812 blown.
- Excessive horizontal size. Pincushion distortion. (WD5516RF tips)
- PSU drops out.
- Line output transistor fails repeatedly.
- Tripping. Red LED blinks. (WD5516RF WINDSOR repair tip)
- Geometry adjustment.
- Stuck in standby. Red LED flashes for a short while.
- Q603 (BU808DFI) overheats.
- Loud noise. in standby.
- Excessive horizontal size. (WINDSOR - WD5516RF information)
- Q801 is defective.
- No functions.
- Goes to standby automatically every 5 min.
- Vertical collapse. (WD5516RF tips)
- Black screen.
- Excessive brightness.
- Slow start-up. when cold.
- Disable hotel mode.
- Line output transistor fails repeatedly. after a few minutes.
- Low audio.
- Vertical fault. Picture is only 5cm high (from the middle of the picture to the bottom).
- Line tearing. (WD5516RF tips)
- Can be switched on via RC or PR +- on appliance only after several attempts.
- No start-up. LED becomes green briefly, then reverts to red.
- No channels.
- When stopping TV via RC, diode stays green and doesn't get red. Picture and sound are OK in standby but line transformer makes a fluttering noise. When restarting via RC, picture, sound and functions are OK.
- Picture height only approx. 15cm and compressed at the bottom.
- PSU pulsates. Red LED blinks.
- Changes the channel after approx. 10 min. on the program site. Switches off when calling up the menu, returns with OSD shifted to the left.
- No start-up. Red LED blinks.
With help of this list a solution is found often when WINDSOR WD5516RF fails.
|
Additionally to repairtips or service information WD5516RF is linked to 163 components (IC's and/or transformers) in the Tectra
database, through which you can identify electrical compatibilities (crossreferences) in
appliances.
|
Chassis information is available (which chassis is built in into WD5516RF ).
EURAS system also knows 536 appliances having the same chassis as WD5516RF and can easily list them.
For WD5516RF there are 5 compatible appliances known and can be listed.
In the repair discussion pinboard for WD5516RF there are 90 replies to questions asked about 76 different repair problems. With access to EURAS you can all read them or enter your own questions and get help for WD5516RF from EURAS technicians or other users.
Do want to see this remedies/cures for repairtips? Register here for the EURAS System
Already registered? open WD5516RF WINDSOR in EURAS
All details on the EURAS System: English |
Deutsch |
Français |
Italiano |
Español |
Magyarul |
Português |
Polski |
Română |
Greek |
Back to EURAS Homepage >>
All manufacturers >>
WINDSOR
tech tips
(C) EURAS International Ltd.
Last updated: 22. Aug 2008 02:06:15 MET, doccode ISO9002AS168EKA200805C EURASMOP
Responsible for the content: EURAS International GmbH, Eime, Germany.
All rights reserved, EURAS database V2.0 (C) 2002-2008.
All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.
|
|