List of fault symptoms:
- No REC.
- Mechanism tries to unload but stops before it gets half-way.
- Horizontal shift.
- On PB, the vertical lines are bent.
- Does not function in Camera mode. (KDM710E YASHICA repair tip)
- Rusted shaft or dirt collected on the shaft cannot be removed using moistened cloth with alcohol.
- No eject.
- Part number information. A new optical filter is used on the new lens assembly. The bulletin shows how to identify these.
- Mechanical operation problem. The reel rotation sensors are easily damaged. (KDM710E tip from YASHICA)
- Certain cassettes stick on the take up reel terminals, resulting in a lacing up or tape transport fault.
- Irregular unloading or ejection of tape under vibration. The cassette compartment may unlock when subject to a mechanical shock after cassette down operation.
- Defective Stop and rewind functions.
- After AC power on, the coaster may vibrate resulting in abnormal initializing.
- Camcorder switches off. Protective circuit symbol blinks.
- The S-reel torque value is out of the specified 17-29 g.cm value (in REV mode). (KDM710E tip from YASHICA)
- Right lacing arm does not load and can be pushed to and fro. (YASHICA - KDM710E information)
- Tape loading not completed.
- Service-Info: Mechanism.
- The reel rotation sensors are easily damaged.
- Take-up reel judders in playback and FF.
- Playback picture jumps.
- Deformed housing bearing.
- The coaster subassembly does not function during loading or unloading.
- Failure to load/eject. Arms move in and out continuously until the fault sign appears.
- No capstan rotation. intermittently.
- No zoom focus, EE is ok.
- No loading. Tape gets chewed or wrinkled. Tape path failure. Coaster subassembly does not function during loading or unloading.
- Iris remains open in automatic mode. Only closes in manual mode.
- Service information. Changes to the mechanical chassis of the U mechanism.
- Black EE picture, playback is ok.
- When EJECT selected, appliance goes to FF then ejects. (KDM710E tips)
- No functions. No eject.
- No eject. Switches off by itself. (KDM710E YASHICA repair tip)
- No mechanical functions.
- The TG3/TG6 guide roller on the left/right coaster assy of U/U' mechanism models may be dislocated.
- Loose LCD assembly.
- Capstan rotates but take-up reel does not.
- Tape stuck.
- Adjustment information. Part of the autofocus adjustment using the Siemens star as detailed in the service manual needs to be modified.
- Difficult cassette lid removal.
- Eats tape.
- Cassette compartment opens intermittently.
- Focus motor does not stop, does not focus.
- Part number information. Part number - S reel table.
- During EJECT, take-up reel spins fast.
- Interference at bottom edge of picture on playback.
- EE and playback picture are dark. EVF display ok. (KDM710E YASHICA repair tip)
- Irregular mechanical operation. Tape path problems.
- No take up. Appliance switches off after a short time.
- Tape spooling out of head, pinch roller not turning.
- Mechanical operation problem. The reel rotation sensors are easily damaged.
- Defective loading.
- Tape guides shift.
- No eject due to shock or external force. (KDM710E YASHICA repair tip)
- No eject. intermittently. (picture attached)
- Irregular mechanical operation. Intermittent loading/unloading.
- TG3/TG6 guide roller on the left/right coaster assy of U/U' mechanism models may be dislocated. (service info for YASHICA -KDM710E)
- Part number information. It is possible for the following two combinations of CRT assembly to be used in the above camcorder.
- Irregular mechanical operation. Intermittent loading/unloading.
- Waterfall effect. (YASHICA - KDM710E information)
- Does not load tape.
- Poor picture or no PB picture. No drum PG.
- Mechanical noise.
- The take up reel functions after switching on, the appliance accepts no commands, and then switches off.
- Does not load tape. No capstan rotation.
- Tape gets chewed/wrinkled. Tape path failure. The coaster subassembly does not function during loading or unloading.
- A tape guide which is positioned in the mechanism is loose and is blocking the loading of the cassette.
- Loading motor does not function. Does not lace up tape.
- Servo motor accelerates and slows down intermittently.
- No threading in.
- A noise bar may appear on the picture during recording or playback (tape path failure).
- Black picture in PB.
- Tape movement: tape curls.
- Dropouts in picture with horizontal lines.
- Picture flickering in PB mode.
- No unloading or ejecting of tape. See also service bulletin CV00194.
- Motor noise. Capstan motor ticking noise.
- The reel torque value is out of the specified 7-19 g.cm value (in FWD mode).
- Appliance blocks occasionally when the tape is unloaded. The loading motor also stops suddenly where it is.
- EE is ok, white screen on playback.
- Large S reel torque fluctuations occur during the REV mode. (YASHICA - KDM710E information)
- Does not load tape. No eject. Fault occurs intermittently. .
- Deformed housing bearing.
- Tape riding up pinch roller.
- Tape entrance and exit path out of alignment.
- The T reel touching the cassette case causes chattering noise during the REV mode. (KDM710E tip from YASHICA)
- No loading. Tape path failure. The coaster subassembly does not function during loading or unloading. (service info for YASHICA -KDM710E)
- No unloading or ejecting of tape. The cassette lid catches and remains open in eject mode so it is not possible to take the cassette out.
- Cassette compartments does not open. (KDM710E tips)
- The roller guide may halt during loading or unloading
- Tape guide roller does not function during lacing up or unlacing.
- Large T reel torque fluctuations occur during playback. (KDM710E YASHICA repair tip)
- Irregular mechanical operation. The reel may stop rotating occasionally and the service mode will display 00:02 or 00:03 (last emergency).
- No unloading or ejecting of tape intermittently. No eject, tape jamming or tape damage especially at the start of a tape.
- Jig availability. Cpa jig for evr adjustments.
- No picture. Dark interferences on screen.
- Auto focus has no function.
- Laces up without a cassette, mode motor shunts forwards and backwards then quits.
- Drum motor functions intermittently. High pitched sound.
- Stripes in Camera mode.
- No eject, drum spins, capstan spins but loading motor doesn't turn.
- Supply tension of the supply reel reduces occasionally from the standard value 9-12 g/cm (in FWD mode) to 2-4 g/cm.
- When loading or unloading tape, appliance blocks intermittently.
- Set does not lace up.
- Tape is damaged. intermittently.
- Tape jams when switching from PLAY to FF and drum stops.
- After switching on both reel motors run at a higher speed.
- Tape damage during review.
- The battery indication is flashing, eject is not possible and the appliance shuts off.
- May not eject at all, or may damage tape by failing to rewind during eject. (KDM710E tips)
- Interference by bright areas in camera mode.
- Defective eject and tape run/battery lamp blinks.
- Service information. This bulletin standardizes repair to U/u' mechanisms. Refer to this bulletin for mechanism problems on this model.
- Extension cable information. Extension cables are available.
- Incorrect tape-end detection.
- Only loads partially.
- No unloading or ejecting of tape intermittently. No eject, tape jamming or tape damage especially at the start of a tape.
- No FF. (YASHICA - KDM710E information)
- Irregular mechanical operation. Tape path problems.
- Does not accept tape.
- No colour in camera picture.
With this service information, you may repair YASHICA KDM710E faster/better when it fails.
When YASHICA KDM710E fails , these symptoms are known and EURAS knows the remedy/solution.
Tips are coming from EURAS customers, workshops and payed technicians from all over the world. YASHICA KDM710E fails can be better solved. If YASHICA KDM710E fails, this information will help you. Here you can only see the symptom list, to access remedies, you must register. With help of this list a solution is found often when YASHICA KDM710E fails.
|
Additionally to repairtips or service information KDM710E is linked to 5 components (IC's and/or transformers) in the Tectra
database, through which you can identify electrical compatibilities (crossreferences) in
appliances.
|
For KDM710E there are 9 compatible appliances known and can be listed.
Do want to see this remedies/cures for repairtips? Register here for the EURAS System
Already registered? open KDM710E YASHICA in EURAS
All details on the EURAS System: English |
Deutsch |
Français |
Italiano |
Español |
Magyarul |
Português |
Polski |
Română |
Greek |
Back to EURAS Homepage >>
All manufacturers >>
YASHICA
tech tips
(C) EURAS International Ltd.
Last updated: 12. Aug 2008 20:31:05 MET, doccode ISO9002AS168EKA200805C [cachelite] EURASMOP
Responsible for the content: EURAS International GmbH, Eime, Germany.
All rights reserved, EURAS database V2.0 (C) 2002-2008.
All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.
|
|