21006 10044292 / ZIENGER [TV 55 (51) cm picture]
The EURAS repair tip database for professional technicians and service engineers
supplies the following faults for 21006 / ZIENGER.
List of fault symptoms:
- No function, mains BU fails repeatedly.
- Dead. LED lit. .
- No S correction.
- Stuck in standby. intermittently. No RC functions. No front panel function. after start-up.
- Picture is too bright and blurred sporadically. Error occurs when CRT board is tapped.
- Insufficient picture height, picture too wide. Delayed operation. No picture during AV, only display.
- Dark picture. after a while.
- Picture is folded over from the top and approx 5 cm are missing from upper picture edge.
- Reduced horizontal size. intermittently.
- Picture too small.
- Ticking noise.
- Line output transistor fails repeatedly.
- No RC functions.
- Power supply cuts out.
- No RC after some time, later ok again. OSD displays tear after some time.
- Geometry fault.
- R639 (10K) burns.
- Appliance does not switch on, no LED display, a constant click from PSU.
- No TXT.
- White horizontal stripes in picture.
- No start-up. intermittently.
- Mains fuse fails immediately after start-up.
- No horizontal synchronisation. Colour fault.
- PSU pulsates. at start-up.
- No start-up. LED blinks .
- Starts up from standby. LED goes green. Intermittent or no picture.
- Shuts down, after a while. Coloured spots remain on screen.
- Primary of PSU pulsating.
- Picture too wide. Height is normal. E/W not ok. Slight bowing in the TXT.
- PSU does not start. LED is off. Low ticking.
- Cannot switch to DK mode via main menu. (service info for ZIENGER -21006)
- No sound menu in main menu and no sound.
- D606 overheats.
- Chirping.
- Top half of picture is black. Flyback lines in the middle. Picture is intermittently OK.
- Buzzing noise from speakers when first turned on. Sometimes picture interference too.
- No picture. Only bright glimmer.
- Oversized picture. Picture rolls over at upper picture edge when TXT is called up. Only blue picture via AV. (ZIENGER - 21006 information)
- Lines in picture. (21006 tip from ZIENGER)
- Power supply fault.
- Enter service mode.
- Small corrugations and no audio after start-up. After warm-up there is gurgling audio. Picture and audio OK after a while.
- No picture. Audio OK .
- Starts up immediately in protective switching. (Pumps.) (21006 tip from ZIENGER)
- Tripping. in standby. (21006 tips)
- Dead. Standby LED flashes .
- E/W fault.
- Horizontal bars run through picture.
- PSU pulsates.
- PSU faulty.
- No picture. TXT OK .
- No HV.
- No start-up. LED is green.
- No tube heaters.
- No start-up.
- No or intermittent start-up. Snow in picture. No RC functions.
- PSU IC800 is defective.
- Squealing from PSU. at start-up.
- Q601(BU2508AF) blows after a few minutes.
- No start up. Standby LED does not light up. Faint ticking from the loudspeakers.
- Audio disappears. 5min timer appears in OSD, then counts down and switches off. Fault occurs intermittently.
- Reduced vertical and horizontal size. No STEREO.
- Reduced vertical and horizontal size.
- No picture. Coloured lines.
- PSU and D800 (BA159) blown.
- No TXT. No OSD.
- No picture. No EHT. Audio OK.
- PSU pumps at start-up.
- D605 S/C immediately.
- Tripping. intermittently.
- Tripping. Standby LED lit .
- Stuck in standby.
- Clicking noise. via speakers (intermittently).
- Beeping sound in STANDBY mode from power supply.
- No vertical deflection.
- No start-up from standby.
- No start-up from standby. LED blinks . Arcing. (service info for ZIENGER -21006)
- Dead. PSU ticking.
- +UB control range is incorrect. +UB cannot be adjusted to minimum 155V.
- No PSU start up.
- E/W fault. Excessive horizontal size.
- Reduced horizontal size. Stripes in picture. on the left.
- Q801 is defective.
- Colour disappears after approx. 20 sec or no colour at switch on.
- EEPROM settings.
- Tripping. Red LED blinks.
- Insufficient E/W defelction, Error decreases when warming up.
- Ticking noise. LED blinks .
- Dead. Tripping audio via left speaker.
- Menu is only in English. Cannot change values in service mode. Picture is in 16/9 format. (service info for ZIENGER -21006)
- No or intermittent picture. Dark picture.
- Picture brightness fluctuates or becomes increasingly darker, may intermittently be completely black.
- Noisy picture. Only a blue square. Sound OK.
- Option codes.
- No E/W correction. Picture too big.
- No CRT heaters.
- PSU switches on only if the value of the trimmer resistor is increased to VR800.
- Popping noise from speakers and squeak from power supply twice a second. Standby LED does not lit.
- Vertical collapse.
- Stuck in standby. Faint ticking noise audible, which changes frequency when keys are pressed.
- No switch on, red LED lit, then green LED flickers.
- No start-up. Standby LED becomes green for a second, then reverts to standby.
- Pulsating picture. Jagged verticals. Picture size varies.
- Memory loss.
- No audio. Popping noise from speakers. No audio options in menu.
- Black line in top and bottom of screen in 16:9 mode.
- Disable child lock.
- Pincushion distortion. Picture too big.
- Switches to standby. intermittently. LED flickers .
- Vertical line.
- Only half a picture, top is black. Picture has folded over.
- Horizontal line.
- No line drive.
- Picture too small. after a few minutes.
- Red standby LED is lit, red changes to green during start via RC. Audible start up attempts.
- Standby OK. When switched on, the appliance tries to start. Cuts up and LED alternates green-red.
- No CRT heater operation.
- Shuts down. after start-up.
- Geometry settings. (service info for ZIENGER -21006)
- No function. Standby LED flashes. Start up attempts audible from the PSU.
- Dark picture (intermittently).
- ATP is performed but no channel stored. All program positions are on channel 5. If channel is input manually, fine tuning drifts off tune. (ZIENGER - 21006 information)
- No audio. No picture.
- Poor picture. Flyback lines.
- LED flashes 2-3 times green and then switches back to standby.
- Reduced vertical size. Excessive horizontal size. No picture. intermittently.
- Switches after start up from standby to green and goes back to standby.
- Remains in standby, LED becomes slightly darker after switch on (1sec) then brighter again.
- Picture appears slowly. Audio OK .
- Tripping.
- Control LED flickers only slightly red, othewise no function.
- Blows D808 in secondary PSU when bringing set out of standby. Squealing from PSU at switch-on.
- White dashes on picture when cold.
- Switches to standby. LED is red .
- Poor vertical linearity. Vertical foldover at bottom.
- No sound. Cannot call up installation menu.
- Stretched picture.
- Switches to standby. Standby LED flashes .
- Tries to start up. LED is green for an instant then becomes red again.
- Excessive vertical and horizontal size.
- No front panel function.
- Dead. Standby LED lit .
- Trips. (21006 ZIENGER repair tip)
- Squealing noise. intermittently.
- BU2508AF fails after a few seconds.
- Dark picture. (service info for ZIENGER -21006)
If ZIENGER 21006 fails, this information will help you. Here you can only see the symptom list, to access remedies, you must register. With help of this list a solution is found often when ZIENGER 21006 fails.
|
Additionally to repairtips or service information 21006 10044292 is linked to 184 components (IC's and/or transformers) in the Tectra
database, through which you can identify electrical compatibilities (crossreferences) in
appliances.
|
Chassis information is available (which chassis is built in into 21006 10044292).
EURAS system also knows 396 appliances having the same chassis as 21006 10044292 and can easily list them.
For 21006 10044292 there are 2 compatible appliances known and can be listed.
In the repair discussion pinboard for 21006 10044292 there are 86 replies to questions asked about 125 different repair problems. With access to EURAS you can all read them or enter your own questions and get help for 21006 from EURAS technicians or other users.
Do you want to see this remedies/cures for repairtips? Register here for the EURAS System Please note: access to the EURAS System can be granted only to professional
Video/technicians/TV/household electronics repair shops which are
authorized for service by a manufacturer, or can prove to be professionally
certified to do repairs on electronic appliances. You will be asked for a
statement and information accordingly during registration.
If you do not qualify as stated above and you have an appliance that needs
technical service, we do recommend you to contact the manufacturer (for
example through his website) or go to a professional household/TV/Video
electronics repair shop close to you.
Already registered? open 21006 ZIENGER in EURAS
All details on the EURAS System: English |
Deutsch |
Français |
Italiano |
Español |
Magyarul |
Português |
Polski |
Română |
Greek |
Back to EURAS Homepage >>
All manufacturers >>
ZIENGER
tech tips
Last updated: 07. Oct 2008 20:09:51 MET, doccode ISO9002AS168EKA200805C EURASMOP
Responsible for the content: EURAS International GmbH, Eime, Germany.
All brand- or productnames are copyrighted by the respective manufacturer of the appliance and are only being used for identification purposes.
|
|